Venous thromboembolic disease (VTED) is a rare complication following arthroscopic rotator cuff repair (RCR). The American Academy of Orthopaedic Surgeons and the American College of Chest Physicians have no prophylaxis guidelines specific to shoulder arthroscopy, yet many surgeons prescribe aspirin following RCR. The purpose of this study was to evaluate the effectiveness of aspirin and mechanical prophylaxis compared with mechanical prophylaxis alone in preventing VTED following RCR. A total of 914 patients underwent RCR between January 2010 and January 2015. A retrospective case-control study was performed. The control group (n=484) consisted of patients treated with compression boots and early mobilization. The study group (n=430) used compression boots, early mobilization, and 81 mg/d of aspirin. The primary outcome was symptomatic VTED, including deep venous thrombosis (DVT) and pulmonary embolism (PE). A total of 7 VTED events occurred during the study period: 6 DVTs and 1 PE; 1 patient experienced both DVT and PE. The percentage of patients with VTED, DVT, and PE was 0.66%, 0.66%, and 0.11%, respectively. There was no significant difference for DVT or PE between the 2 groups. The incidence of DVT and PE was 0.62% and 0.00%, respectively, for the control group (no aspirin) and 0.70% and 0.23%, respectively, for the study group (aspirin). Aspirin does not lead to a clinically significant reduction in either DVT or PE rate in patients undergoing RCR. The authors conclude that the use of mechanical prophylaxis and early mobilization is a sufficient method of VTED prophylaxis in this low-risk population. [ Orthopedics . 2019; 42(2):e187–e192.]
Background: The present study intended to identify debris in the spine surgical field that frequently rises to the level of the surgeon's face during several different elective spine procedures. Unlike other areas of orthopedic surgery where infection risk is of high concern, in spine surgery the surgical team usually uses a nonsterile face mask instead of a protective space suit with a sterile face shield. It is possible that blood or bone burr particles striking the surgeon's face mask represent a potential source of infection if they ricochet back into the operative field. Methods: We reviewed 46 consecutive, elective spine surgeries between May 2015 and August 2015 from a singlesurgeon practice. For each surgery, every member of the surgical team wore sterile (space suit) personal protective equipment. After each procedure, the face shield was carefully inspected by 2 members of the surgical team to identify patient blood, tissue, or bone burr dust present on the face shield. Results: The rate of surgeon face shield debris inspected for each case overall was 38/46 (83%). The rate of first assistant face shield debris inspected per case was 16/46 (35%). The scrub technician had a 0% rate of face mask debris on inspection. The highest debris exposure rates occurred with transforaminal lumbar interbody fusions (100%), open laminectomy and fusions (100%), and anterior cervical discectomy and fusions 43/46 (93%). Conclusions: There is a high rate of blood and tissue debris contact that occurs during spine surgery, and it is procedure dependent. Spine surgeons may consider using sterile shields particularly in high-risk cases to protect themselves and their patients. Level of Evidence: 4.
Background: Three-dimensional custom cages can be used to treat complex ankle and hindfoot pathology and bone loss with potentially better patient satisfaction and higher fusion rates than tibiotalocalcaneal (TTC) fusion alone or in combination with bulk femoral head allograft. Yet there is limited literature to support this procedure. The purpose of this study is to objectively quantify the clinical and radiologic outcomes of patients undergoing patient-specific 3D-printed custom cage implantation to fill large defects around the ankle joint region as part of a limb-salvaging TTC fusion. Methods: This is a retrospective review of 21 patients (mean age 59.3 years) who underwent custom cage implantation with a TTC retrograde fusion nail by a single surgeon for massive bone loss of the ankle and hindfoot. Patient charts were reviewed for pain and functional outcomes, complications, and various demographics, including number of previous surgeries to the ipsilateral ankle. Mean follow-up was 32 months. All 21 patients had preoperative and postoperative pain and function scores available for analysis. Results: A total of 20 (95.2%) of the 21 patients had their cage in situ at final follow-up. Overall, with the numbers available, visual analog scale (VAS) for pain, Foot and Ankle Ability Measure (FAAM) activities of daily living subscale, and the 12-Item Short Form Health Survey (SF-12) mental and physical health scores significantly improved from preoperative to final follow-up. However, when compared to the overall US population of age-matched 55- to 64-year-old individuals, patients still remained relatively disabled. There were 2 failures, one of which required amputation and the other was treated nonoperatively with bracing. Conclusion: In conclusion, in this relatively small, single-surgeon series, we found that 3D-printed custom cage technology offered a viable option for complex TTC fusion procedures performed in the presence of significant bone loss, with good fusion rates, however relatively modest improvement in functional outcomes. Level of Evidence: Level IV, retrospective case series.
Burnout among physicians is a syndrome of emotional exhaustion, de-personalization, and reduced sense of personal accomplishment that can negatively affect personal relationships, physician well-being, and patient outcomes. Although burnout rates of up to 50% to 60% among orthopedic surgeons have been reported, no studies have evaluated burnout among orthopedic generalists and subspecialists. The primary goal of this study was to examine the prevalence of burnout among orthopedic disciplines. We conducted a multicenter study from March 2019 through December 2019 involving 149 orthopedists. An abbreviated Maslach Burnout Inventory-Human Services Survey was used to measure burnout. Demographic information, personal characteristics, professional characteristics, family life and spousal support, and depression were also assessed. The mean rate of burnout among all respondents was 62%, whereas 16.77% screened positive for depression. Subspecialties with the highest rates of burnout were oncology (100%), sports medicine (68%), and trauma (63%). Similarly, trauma (50.00%), oncology (40.00%), and general orthopedics (20.00%) had the highest positive depression screening rates. In contrast, shoulder and elbow (50%), pediatric (52%), and foot and ankle (54%) specialists had the lowest rates of burnout, whereas shoulder and elbow (0.00%), spine (0.00%), and sports medicine (6.50%) specialists had the lowest rates of positive depression screening. Older age, higher debt load, and oncology subspecialty were associated with increased burnout risk. This study sought to determine burnout rates within each orthopedic discipline, with a secondary aim of disclosing contributing factors. Trauma and oncology had the highest rates of burnout and positive depression screening. Because this study represents a small orthopedic cohort, larger studies are needed to appropriately manage burnout in the future. [ Orthopedics . 2022;45(6):333–339.]
Metal allergy to total ankle arthroplasty is rare but can be both an unpredictable and devastating complication. Current literature describing metal allergy in orthopaedics is limited with there being no report to date on metal allergy after total ankle arthroplasty. Our patient underwent a total ankle arthroplasty and developed a diffuse rash 7 weeks postoperatively. The patient then tested positive for a metal allergy and ultimately was converted to an arthrodesis. In the setting of postoperative pain, swelling, erythema, or rash, it is important that metal allergy be on the differential diagnosis. Interestingly, when the patient here underwent allergy testing, only the articulating sides of the implant caused a positive reaction. Thus, allergy testing of both the articular and nonarticular sides of the component is of the utmost importance, as evidenced by the discrepancy found in this case. Levels of Evidence: Level IV: Case report
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.