Dental alloys for direct metal laser sintering (DMLS) are available on the market today, but there is little scientific evidence reported on their characteristics. One of them is the release of ions, as an indicator of the corrosion characteristics of a dental alloy. Within this research, the difference in the elution of metals from DMLS and cast (CM) samples of Co-Cr-Mo dental alloy in saliva-like medium of three different pH was examined by inductively-coupled plasma mass spectrometry (ICP-MS). The obtained results show that the metal elution in artificial saliva from the DMLS alloy was lower than the elution from the CM alloy. The release of all investigated metal ions was influenced by the acidity, both from the DMLS and CM alloy, throughout the investigated period of 30 days. The change in acidity from a pH of 6.8 to a pH of 2.3 for the cast alloy led to a higher increase of the elution of Co, Cr and Mo from CM than from the DMLS alloy. The greatest release out of Co, Cr and Mo was for Co for both tested alloys. Further, the greatest OPEN ACCESSMaterials 2014, 7 6487 release of all ions was measured at pH 2.3. In saliva of pH 2.3 and pH 4.5, the longer the investigated period, the higher the difference between the total metal ion release from the CM and DMLS alloys. Both alloys showed a safe level of elution according to the ISO definition in all investigated acidic environments.
The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family -two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.
The aim of this study was to determine the cytotoxicity of a Co-Cr alloy used for the rapid manufacture of removable partial denture frameworks using murine fibroblasts L929 cell lines and three test methods: the MTT assay, the agar diffusion test (ADT) and the dye exclusion test (DET). Two groups of disc specimens (5 mm diameter, 1 mm thick) were fabricated. The first group was cast using a conventional method (CM) in a Nautilus CC casting. The second group was fabricated using selective laser melting (SLM) in SLM Realiser The total cell number and viability of cells pre-incubated with CM and SLM alloys were comparable to the control sample. Differences between the growth inhibitory effects of the CM and SLM alloys in the MTT assay were below 30 %. Results of two independent agar diffusion tests with CM and SLM alloys showed neither detectable discoloration around or under the discs nor a detectable difference in staining intensity. As the cell response for both CM and SLM alloys was 0/0, the discs can be rated as noncytotoxic. The results suggested that the F75 Co-Cr alloy used for the SLM process did not release harmful material that could cause acute effects against L929 cells under the given experimental conditions.
Key advantages of Poly(methyl methacrylate)—PMMA for denture application are related to aesthetics and biocompatibility, while its main deficiency is related to mechanical properties. To address this issue, SiO2 nanoparticle reinforcement was proposed, containing 0 to 5% nanosilica, to form nanocomposite materials. Flexural strengths and elastic moduli were determined and correlated to nominal nanoparticle content and zeta potential of the liquid phase nanoparticle solutions. Another issue is the biocompatibility, which was determined in terms of cytotoxicity, using L929 and MRC5 cell lines. The addition of nanoparticle was proved to be beneficial for increasing flexural strength and modulus, causing a significant increase in both strength and moduli. On the other hand, the formation of agglomerates was noted, particularly at higher nanoparticle loadings, affecting mechanical properties. The addition of nanosilica had an adverse effect on the cytotoxicity, increasing it above the level present in unmodified specimens. Cytotoxic potential was on the acceptable level for specimens with up to 2% nanosilica. Consequently, nanosilica proved to be an effective and biocompatible means of increasing the resistance of dental materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.