A new optical condition using an objective lens (OL) of a long focal length (objective mini lens: OM) was tested to enhance image contrast in phase plate transmission electron microscopy (P-TEM). A phase plate was set on the selected area aperture plane where diffraction patterns were formed under the optical condition using the OM. A phase shift by the phase plate was added to the electron waves to visualize phase objects. The application of the OM to the P-TEM should provide higher phase contrast than that obtained by the OL for the phase objects. One of the reasons for the contrast enhancement is that high-angle scattering electron waves which would give the background intensity were not used for image formation due to the large spherical aberration. Another reason is that the cut-on frequency above which the phase shift was added by the phase plate could be smaller using the OL with a long focal length. Experimental results and model calculations showed the contrast enhancement of the biological specimens using the OM.
Structural investigation of protein motion is one of the important ways to understand cell motility. We have studied structural changes of myosin molecules induced by ATP application by using an environmental TEM (E-TEM) [1,2]. An image contrast of the myosin heads is very weak due to a weak interaction between myosin molecules and electron beam. Colloidal gold particles were attached to the myosin heads with cite directed antibody, and the structural changes were investigated through the changes in the position of the gold particles. Direct observations of the biological molecules should be the most direct way to study the structural investigations. We have been developing a combination method of E-TEM and a phase contrast TEM (P-TEM) to obtain phase contrast of the biological molecules in water and the biological molecules in water could be visualized [3]. Image contrast was reduced due to increase in background intensity cause by inelastic scattering by ambient water. Intensity of incident electron beam should be suppressed to avoid electron damage of the specimen. Thus, very high contrast imaging is required for direct observation without stain.We have tried to enhance image contrast by using an objective lens with long focal length (OL-LFL) [4]. A phase plate was set on the selected area (SA) aperture plane and a diffraction pattern was formed by using the OL-LFL on the plane. Figure 1 shows ray diagrams for two optical conditions and figs. 2(a)-(c) are images taken under a conventional TEM condition, a conventional P-TEM condition and the P-TEM condition using OL-LFL. However, black dots correspond to colloidal gold particles are seen in all the images, myosin filaments are seen only by P-TEM and there was no contrast in C-TEM. Moreover, the image contrast of the myosin filaments in (c) is higher than that in (b). Thus, it can be claimed that application of the OL-LFL to the P-TEM provided higher phase contrast of phase objects than that obtained by application of a conventional objective lens to the P-TEM. A reason for the contrast enhancement is that high angle scattering waves which give the background intensity were not used for image formation under this optical condition.
References
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.