To analyze surgical results of 32 cases with acute acquired comitant esotropia (AACE) related to prolonged use of digital devices (DDs). Patients and Methods: Medical records of cases with AACE related to prolonged use of DDs that had undergone surgery were retrospectively revised. Complete medical history and full ophthalmological examinations before and surgery were obtained for all cases. All cases also underwent neurological examinations using brain and orbital imaging. Motor success was considered as alignment within 10 prism diopters (Δ) at both near and distance. Sensory success was defined as stereopsis ≤60 arcsec. Nineteen cases (Group S) underwent surgery alone and 13 cases were treated with surgery and prism adaptation (Group S+P). Motor and sensory outcomes were compared between groups. Results: Mean age at first visit was 22.0 ± 9.0 years and mean daily use of DDs use was 6.3 ± 3.4 hours. Mean angle of preoperative alignment for distance and near were 26.5 ± 13.0Δ and 24.6 ± 16.4Δ, respectively. Surgery was performed at a mean of 23.3 ±3.5 years old and mean angle of alignment at final examination for distance and near were 5.8 ± 7.7Δ and 3.5 ± 5.7Δ, respectively. Final motor and sensory success rate were 84% and 53%, respectively. No significant differences in motor or sensory outcomes were evident between groups at initial or last visit. Conclusion: Favorable motor and sensory outcomes were achieved with surgical intervention with and without prism adaptation for AACT related to prolonged use of DDs.
To determine the reliability of the Kinect-based semi-automatic scoring method (KSSM) using Kinect for Windows v2 for head posture compared to the cervical range-of-motion (CROM) device. Methods and Analysis: Head positions between −40° and +40° of chin up/down (X), head turn (Y), and lateral tilt (Z) were measured in 10° increments in healthy volunteers. Their head positions were simultaneously measured using the KSSM and CROM. The following four points were analyzed: the success rate of the KSSM, the correlation between the two methods, the comparison of results by 95% limits of agreement (LA), and proportional error at 95% LA. Results: The measurability of the KSSM for all positions within ±30° of the X, Y, and Z axes was 100%. The correlations for both methods were 0.979 (95%
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.