The study of airflow and contaminant transport in airliner cabins is very important for creating a comfortable and healthy environment. This paper shows the results of such a study by conducting experimental measurements and numerical simulations of airflow and contaminant transport in a section of half occupied, twin-aisle cabin mockup. The air velocity and air temperature were measured by ultrasonic and omni-directional anemometers. A gaseous contaminant was simulated by a tracer gas, sulfur hexafluoride or SF 6 , and measured by a photoacoustic multi-gas analyzer. A particulate contaminant was simulated by 0.7 μm Di-Ethyl-HexylSebacat (DEHS) particles and measured by an optical particle sizer. The numerical simulations used the Reynolds averaged Navier-Stokes equations based on the RNG k-ε model to solve the air velocity, air temperature, and gas contaminant concentration; and employed a Lagrangian method to model the particle transport. The numerical results quantitatively agreed with the experimental data while some remarkable differences exist in airflow distributions. Both the experimental measurements and computer simulations were not free from errors. A complete and accurate validation for a complicated cabin environment is challenging and difficult.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.