A risk assessment for this National Priority List (NPL) site evaluated the magnitude of the public health impact, assuming that no remediation had or would occur at a landfill. The purpose of the groundwater modeling effort was to predict future groundwater concentrations after liner failure at a residential well currently using the ground water. A two‐dimensional, transient, instantaneous‐release, multipoint‐source model was used to estimate the groundwater concentration at the residential well for 120 years after the release. A worst‐case concentration in ground water was calculated by assuming that no retardation or degradation (chemical or biological) would occur. A more realistic concentration was determined by developing a retardation factor. The modeled groundwater concentrations that were simulated did not exceed standards. If no remediation were to occur and worst‐case liner failure did occur, then the population would still not be at an unacceptable risk from consuming impacted ground water as a potable water supply. In reality, the predicted worst‐case exposure concentrations are unlikely to be reached, and the population (i.e., few individuals) might not be exposed.
A risk assessment for this National Priority List (NPL) site evaluated the magnitude of the public health impact, assuming that no remediation had or would occur at a landfill. The purpose of the groundwater modeling effort was to predict future groundwater concentrations after liner failure at a residential well currently using the ground water. A two-dimensional, transient, instantaneous-release, multipoint-source model was used to estimate the groundwater concentration at the residential well for 120 years after the release. A worst-case concentration in ground water was calculated by assuming that no retardation or degradation (chemical or biological) would occur. A more realistic concentration was determined by developing a retardation factor. The modeled groundwater concentrations that were simulated did not exceed standards. If no remediation were to occur and worst-case liner failure did occur, then the population would still not be at an unacceptable risk from consuming impacted ground water as a potable water supply. In reality, the predicted worst-case exposure concentrations are unlikely to be reached, and the population (i.e., few individuals) might not be exposed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.