Uniform illumination is a key requirement in different research fields. However, this requirement is often difficult to achieve when high intensity is required at the same time. Recent advancements in LED lamps allow nowadays for compact and economical solutions. In this work we present a suitable solution for various laboratory purposes requiring stable, uniform and high intensity illumination. The system is composed of four identical high power white LED arrays of 30 mm diameter each, placed on a supporting and cooling structure having a minimum volume of 26 cm x 26 cm x 8 cm. A numerical model has been developed, based on a ray tracing software, in order to simulate the performances. These have then been experimentally validated with measurements of the power density map, carried out with a 1% uncertainty pyranometer. Data show that the built system is very stable over time and provides an illumination uniformity higher than 98%, on a surface of 50 mm radius, which reduces to 95% on a surface of 75 mm radius. The power density can be adjusted in the 390-1360 W m-2 range, not affecting uniformity.
Among solar thermal collectors, the evacuated flat panel is emerging as a reference technology for operation at higher temperatures of up to 200 °C with an increased annual energy production owing to both direct and diffuse light capture. Accurate measurements of the optical properties of the selective absorbers used in such devices are key for a reliable estimation of the overall performance. These optical properties must be measured under high vacuum at high temperatures, conditions under which the panels are meant to operate. In this study, we accurately measured these properties using a calorimetric technique. The measurement procedure is based on a power balance equation for a flat sample suspended in a high-vacuum chamber with minimal thermal losses and is well adapted for this class of devices. Calorimetric measurements obtained under Sun and LED light revealed excellent reproducibility and good agreement with those obtained using traditional optical analysis at low temperatures in air. When extended up to the absorber stagnation temperature, which often exceeds 300 °C, the calorimetric measurements started to deviate from the optical measurements, indicating the importance of measuring under the operating conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.