IntroductionA new arthroscopic shoulder stabilisation procedure is proposed, which for some patients could be an alternative to the arthroscopic Latarjet procedure.MethodsThe objective was to stabilize the shoulder by making a sling around the subscapularis tendon, using a hamstring graft and enhancing the anterior rim of the glenoid with the same graft. The anatomical feasibility of the surgical procedure was tested to establish the surgical method.ResultsFour surgeons performed the surgery on six cadavers. After the surgery the cadavers were dissected to visualize the result. The sling was placed according to the intention and the nerves in the area (axillary and musculocutaneus) were not at risk, nor had they altered position during the procedure.ConclusionThe procedure is technically feasible and the risk of complications seems low. This procedure could be an alternative to the Latarjet procedure and to other operations used for anterior instability of the shoulder. A biomechanical study will be performed as the next stage of the development.Clinical relevanceThis procedure could be an alternative to the Latarjet procedure and to other operations used for anterior instability of the shoulder.Trial registration2012/1978/REK sør-øst
There are numerous arthroscopic techniques available to address anterior shoulder instability. Complications are various, and in pursuit of new treatment options, an alternative arthroscopic technique with less potential for complications has been developed. The novel subscapular sling with a semitendinosus graft provides both dynamic and static stability. This procedure uses a semitendinosus graft as a sling around the upper two-thirds of the subscapular tendon, attached to the anterior glenoid rim. The sling phenomenon present in the Latarjet procedure was the basis of the development. The efficacy of the subscapular sling procedure has been verified in biomechanical studies and further investigated in a clinical pilot study. The procedure can be performed without altering the anatomy of nearby structures such as the coracoid process, the conjoined tendon, and the axillary and musculocutaneous nerves. The authors propose the arthroscopic subscapular sling procedure as an alternative to existing surgical treatment options for recurrent anterior shoulder instability.
Purpose This novel arthroscopic subscapular sling procedure stabilizes the shoulder using a semitendinosus graft to create a sling around the subscapular tendon, which provides both static and dynamic stability. The aim of the study was to evaluate the biomechanical stability of the subscapular sling procedure in human cadaveric shoulders. The hypothesis was that the sling offers an equal stabilizing effect and range of motion compared to an arthroscopic Bankart repair. Methods Sixteen shoulders were investigated using an industrial robot-based testing platform and four different conditions: the physiologically intact shoulder, after creating a Bankart lesion, after arthroscopic Bankart repair, and finally after applying the subscapular sling procedure using a semitendinosus tendon graft. Joint translation and external rotation were evaluated for each condition. ResultsThe results show improved stability in the shoulders with the subscapular sling. The robot testing revealed a significant reduction in translation in anterior and anterior-inferior directions compared to the arthroscopic Bankart repair. None of the shoulders were dislocated by forced manual abduction and external rotation. No difficulties were encountered in performing the arthroscopic subscapular sling procedure. Thorough postoperative anatomical dissection showed no alterations to structures at risk. ConclusionThe biomechanical results show increased stability with the use of the subscapular sling method.
Purpose Treatment of anterior glenoid bone loss in patients with recurrent anterior shoulder instability is a challenge. The subscapular sling method with quadriceps tendon bone (QTB) graft is a modification of the subscapular sling with a semitendinosus (ST) graft. The aim of the study was to test the biomechanical stability of the QTB sling procedure in human shoulder cadavers with severe anterior glenoid bone loss. Methods Fourteen cadaveric shoulders were tested with a force-moment-guided robot in three conditions: physiologically intact, anterior glenoid bone resection, and the subscapular sling procedure with a QTB graft. Joint stability was measured in anterior, anterior inferior and inferior directions in four glenohumeral joint positions: 0° and 60° of glenohumeral abduction, with each at 0° and 60° of external rotation. Maximum external rotation was measured at 0° and 60° glenohumeral abduction. Computer tomography scans were obtained preoperatively to plan the glenoid bone resection, as well as postoperatively to calculate the proportion of the glenoid bone actually resected. Results Significantly decreased translations were observed in the shoulders with the QTB sling compared to the intact joint and the glenoid bone loss model. No significant differences in maximum external rotation were observed between the three different conditions. Conclusion This biomechanical study revealed a significant stabilizing effect of the arthroscopic subscapular QTB graft sling procedure in human shoulder cadavers without compromising external rotation. Clinical trials may reveal the usefulness of this experimental method. Keywords Shoulder instability • Arthroscopic sling procedure • Quadriceps tendon bone graft • Subscapular tendon • Biomechanical cadaver study • Glenoid bone loss This project involves highly qualified orthopedic surgeons from
In this paper, we examine the region- and layer-specific collagen fiber morphology via second harmonic generation (SHG) in combination with planar biaxial tension testing to suggest a structure-based constitutive model for the human meniscal tissue. Five lateral and four medial menisci were utilized, with samples excised across the thickness from the anterior, mid-body, and posterior regions of each meniscus. An optical clearing protocol enhanced the scan depth. SHG imaging revealed that the top samples consisted of randomly oriented fibers with a mean fiber orientation of 43.3o. The bottom samples were dominated by circumferentially organized fibers, with a mean orientation of 9.5o. Biaxial testing revealed a clear anisotropic response, with the circumferential direction being stiffer than the radial direction. The bottom samples from the anterior region of the medial menisci exhibited higher circumferential elastic modulus with a mean value of 21 MPa. The data from the two testing protocols were combined to characterize the tissue with an anisotropic hyperelastic material model based on the generalized structure tensor approach. The model showed good agreement in representing the material anisotropy with a mean r2 = 0.92.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.