Medical uses of radiation have grown very rapidly over the past decade, and, as of 2007, medical uses represent the largest source of exposure to the U.S. population. Most physicians have difficulty assessing the magnitude of exposure or potential risk. Effective dose provides an approximate indicator of potential detriment from ionizing radiation and should be used as one parameter in evaluating the appropriateness of examinations involving ionizing radiation. The purpose of this review is to provide a compilation of effective doses for radiologic and nuclear medicine procedures. Standard radiographic examinations have average effective doses that vary by over a factor of 1000 (0.01-10 mSv). Computed tomographic examinations tend to be in a more narrow range but have relatively high average effective doses (approximately 2-20 mSv), and average effective doses for interventional procedures usually range from 5-70 mSv. Average effective dose for most nuclear medicine procedures varies between 0.3 and 20 mSv. These doses can be compared with the average annual effective dose from background radiation of about 3 mSv.
The U.S. National Council on Radiation Protection and Measurements and United Nations Scientific Committee on Effects of Atomic Radiation each conducted respective assessments of all radiation sources in the United States and worldwide. The goal of this article is to summarize and combine the results of these two publicly available surveys and to compare the results with historical information. In the United States in 2006, about 377 million diagnostic and interventional radiologic examinations and 18 million nuclear medicine examinations were performed. The United States accounts for about 12% of radiologic procedures and about one-half of nuclear medicine procedures performed worldwide. In the United States, the frequency of diagnostic radiologic examinations has increased almost 10-fold (1950-2006). The U.S. per-capita annual effective dose from medical procedures has increased about sixfold (0.5 mSv [1980] to 3.0 mSv [2006]). Worldwide estimates for 2000-2007 indicate that 3.6 billion medical procedures with ionizing radiation (3.1 billion diagnostic radiologic, 0.5 billion dental, and 37 million nuclear medicine examinations) are performed annually. Worldwide, the average annual per-capita effective dose from medicine (about 0.6 mSv of the total 3.0 mSv received from all sources) has approximately doubled in the past 10-15 years.
Medical radiation exposure of the U.S. population has not been systematically evaluated for almost 25 y. In 1982, the per capita dose was estimated to be 0.54 mSv and the collective dose 124,000 person-Sv. The preliminary estimates of the NCRP Scientific Committee 6-2 medical subgroup are that, in 2006, the per capita dose from medical exposure (not including dental or radiotherapy) had increased almost 600% to about 3.0 mSv and the collective dose had increased over 700% to about 900,000 person-Sv. The largest contributions and increases have come primarily from CT scanning and nuclear medicine. The 62 million CT procedures accounted for 15% of the total number procedures (excluding dental) and over half of the collective dose. Nuclear medicine accounted for about 4% of all procedures but 26% of the total collective dose. Medical radiation exposure is now approximately equal to natural background radiation.
Compared with standard FBP reconstruction, an ASIR algorithm improves image quality and has the potential to decrease radiation dose at low-tube-voltage, high-tube-current multidetector abdominal CT during the late hepatic arterial phase.
EDs and organ doses from 64-detector CT are higher than those previously reported for adult cardiac and pulmonary CT angiography protocols. Risk for breast and lung cancer induction from these studies is greatest for the younger patient population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.