The incidence of infectious syphilis in men who have sex with men and human immunodeficiency virus-infected patients has increased steadily in Victoria, Australia, since 2002. A TaqMan real-time PCR assay targeting the polA gene of Treponema pallidum (TpPCR) was developed. The analytical sensitivity of the assay was estimated to be 1.75 target copies per reaction. Initially, the assay was used to test a variety of specimens (excluding blood) from 598 patients. Of the 660 tests performed, positive PCR results were obtained for 55 patients. TpPCR results were compared with serology results for 301 patients being investigated for early syphilis. Of these patients, 41 were positive by both TpPCR and serology, 246 were negative by both TpPCR and serology, 4 were TpPCR positive but negative by serology, and 10 were TpPCR negative but showed evidence of recent or active infection by serology. Directly compared with serology, TpPCR showed 95% agreement, with a sensitivity of 80.39% and a specificity of 98.40%. Potential factors leading to the discrepant results are discussed. Concurrent serology on 21 patients with TpPCR-positive primary syphilitic lesions demonstrated that a panel of current syphilis serological tests has high sensitivity for the detection of early syphilis. We found that TpPCR is a useful addition to serology for the diagnosis of infectious syphilis. Direct comparison with other T. pallidum PCR assays will be required to fully assess the limitations of the assay.Since 2002, there has been a marked increase in the number of cases of locally acquired syphilis infection in Victoria, Australia (2). Most cases were detected in men who have sex with men, with a disproportionate number of cases in human immunodeficiency virus (HIV)-infected patients (3).Clinical suspicion, and recognition of the symptoms and signs of syphilis, supported by serology is the mainstay of syphilis diagnosis, as direct detection methods such as dark-field microscopy and direct immunofluorescence are relatively insensitive, require fresh high-quality specimens, and are unsuitable for use on specimens from mucosal sites or if superinfection is present (4). Serology may be problematic in the early stages of primary syphilis, as rapid plasma reagin assay (RPR) responses may take some time to develop (4), particularly in HIV-infected patients, and few laboratories in Australia routinely use immunoglobulin M (IgM) assays.The Victorian Infectious Diseases Reference Laboratory (VIDRL) acts as the state reference laboratory for syphilis serology, confirming positive results from other laboratories and offering less commonly used tests, such as IgM assays. The laboratory also provides primary diagnostic services to a number of Melbourne sexually transmitted infection (STI) clinics and receives large numbers of specimens for culture or PCR for other agents of STI, allowing easy access to specimens for the development and assessment of novel STI detection assays. Our aim was to develop a robust, sensitive, and specific realtime PCR assay to d...
Background: Robust serological assays are essential for long-term control of the COVID-19 pandemic. Many recently released point-of-care (PoCT) serological assays have been distributed with little pre-market validation. Methods: Performance characteristics for five PoCT lateral flow devices approved for use in Australia were compared to a commercial enzyme immunoassay (ELISA) and a recently described novel surrogate virus neutralisation test (sVNT). Results: Sensitivities for PoCT ranged from 51.8% (95% CI 43.1 to 60.4%) to 67.9% (95% CI 59.4-75.6%), and specificities from 95.6% (95% CI 89.2-98.8%) to 100.0% (95% CI 96.1-100.0%). Overall ELISA sensitivity for either IgA or IgG detection was 67.9% (95% CI 59.4-75.6), increasing to 93.8% (95% CI 85.0-98.3%) for samples >14 days post symptom onset. Overall, sVNT sensitivity was 60.9% (95% CI 53.2-68.4%), rising to 91.2%% (95% CI 81.8-96.7%) for samples collected >14 days post-symptom onset, with a specificity 94.4% (95% CI 89.2-97.5%), Conclusion: Performance characteristics for COVID-19 serological assays were generally lower than those reported by manufacturers. Timing of specimen collection relative to onset of illness or infection is crucial in the reporting of performance characteristics for COVID-19 serological assays. The optimal algorithm for implementing serological testing for COVID-19 remains to be determined, particularly in low-prevalence settings.
Background Robust serological assays are essential for long-term control of the COVID-19 pandemic. Many recently released point-of-care (PoCT) serological assays have been distributed with little premarket validation. Methods Performance characteristics for 5 PoCT lateral flow devices approved for use in Australia were compared to a commercial enzyme immunoassay (ELISA) and a recently described novel surrogate virus neutralization test (sVNT). Results Sensitivities for PoCT ranged from 51.8% (95% confidence interval [CI], 43.1%–60.4%) to 67.9% (95% CI, 59.4%–75.6%), and specificities from 95.6% (95% CI, 89.2%–98.8%) to 100.0% (95% CI, 96.1%–100.0%). ELISA sensitivity for IgA or IgG detection was 67.9% (95% CI, 59.4%–75.6%), increasing to 93.8% (95% CI, 85.0%–98.3%) for samples >14 days post symptom onset. sVNT sensitivity was 60.9% (95% CI, 53.2%–68.4%), rising to 91.2% (95% CI, 81.8%–96.7%) for samples >14 days post symptom onset, with specificity 94.4% (95% CI, 89.2%–97.5%). Conclusions Performance characteristics for COVID-19 serological assays were generally lower than those reported by manufacturers. Timing of specimen collection relative to onset of illness or infection is crucial in reporting of performance characteristics for COVID-19 serological assays. The optimal algorithm for implementing serological testing for COVID-19 remains to be determined, particularly in low-prevalence settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.