We describe a method for the preparation of a polyurethane phantom to simulate the optical properties of biologic tissues at two wavelengths in the visible and near-infrared spectral range. We characterize the addition of added molecular absorbers with relatively narrow absorption bands [full width at half maximum (FWHM) 32 and 76 nm for Epolight 6084 and 4148, respectively] for independent absorption at 690 nm for absorption up to 5 cm(-1), and 830 nm for absorptions up to 3 cm(-1). Absorption by both dyes is linear with concentration in these respective regions and is consistent in polyurethane both before and after curing. The dyes are stable over long durations with no more than 4% change. The absorption of visible light by polyurethane decreases with time and is stable by one year with a drop of 0.03+/-0.003 cm(-1) from 500 to 830 nm. The scattering properties are selected by the addition of TiO2 particles to the polyurethane, which we functionally describe for the 690- and 830-nm wavelengths as related to the weight per volume. We demonstrate that the variation in absorption and scattering properties for large batch fabrication (12 samples) is +/-3%. The optical properties of the phantoms have not significantly changed in a period of exceeding one year, which makes them suitable for use as a reference standard.
Hemostasis in the traumatized liver has been achieved by thermally denaturing topically applied albumin. In this article, the mechanical properties of liver and denatured albumin (solder) were measured, and the failure methods of liver repaired with albumin were identified. The ultimate tensile strength and Young's modulus were measured for healthy liver (N = 20) and thermally damaged liver (N = 20). The ultimate tensile strength and Young's modulus were measured for three concentrations of coagulated albumin (25, 38, and 53%) in a single layer and for two layers of denatured 38% albumin. Failure under tension of argon-beam coagulator soldered liver on the parenchymal surface (N = 30) with 38% albumin in two layers had a 70% occurrence for tearing at a mean stress of 39 kPa and a 23% occurrence for shearing at a mean stress of 7 kPa. Liver repaired on the interior surface (N = 11) failed in tension by tearing (64%) at a mean stress of 34 kPa and by shearing (36%) at a mean stress of 6 kPa. Argon-beam coagulator soldering with 38% albumin took 6 s/cm(2) for two layers of solder and gave the best balance of usability, strength, and matching of mechanical properties with those of the liver.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.