A new prestructured target plate for matrix-assisted laser desorption/ionization (MALDI) was developed specifically for hydrophobic integral membrane proteins. This sample support contains predefined concentrating sample spots with a focusing effect on droplets with a high content of hexafluoroisopropanol (HFIP). This fluorinated organic solvent is advantageous for solubilizing hydrophobic proteins that are not soluble in water or the organic solvents normally used in sample preparation protocols for MALDI-MS. The prestructured plate was constructed by coating a regular steel plate with a thin layer of a silicone polymer, leaving sample spots of bare steel. Fabrication of the concentrating silicone structure was fast and very straightforward, without expensive or complicated equipment. Removing the layer, and thus regenerating the steel plate, was done by a simple washing procedure. The application and cleaning procedure are not constrained by a particular design of sample support or to any specific brand of mass spectrometer. When using the prestructured MALDI plate with HFIP as the sample solvent for 17 pmol of a cyanogen bromide digest of the highly hydrophobic membrane protein bacteriorhodopsin, an improved focusing effect and an increase of more than five-fold in average sensitivity were observed, compared with a regular steel target. Experimental results show a two-fold increase in average sensitivity when the new prestructured target plate was used, compared with a commercially available concentrating support.
A new method, involving SPE and HPLC/UV diode-array detection (DAD), was developed for the quantification of colophonium components in different consumer products, such as cosmetics. Colophonium is a common cause of contact dermatitis since its components can oxidize into allergens on exposure to air. Three different resin acids were used as markers for native and oxidized colophonium, abietic acid (AbA), dehydroabietic acid (DeA), and 7-oxodehydroabietic acid (7-O-DeA). The SPE method, utilizing a mixed-mode hydrophobic and anion exchange retention mechanism, was shown to yield very clean extracts. The use of a urea-embedded C(12) HPLC stationary phase improved the separation of the resin acids compared to common C(18). Concentrations higher than 2 mg/g of both AbA and DeA were detected in wax strips. In this product also 7-O-DeA, a marker for oxidized colophonium, was detected at a level of 28 microg/g. The LODs were in the range of 7-19 microg/g and the LOQs 22-56 microg/g. The method is simple to use and can be applied on many types of technical products, not only cosmetics. For the first time, a method for technical products was developed, which separates AbA from pimaric acid.
The widespread use of scented products causes an increase of allergic contact dermatitis to fragrance compounds in Western countries today. Many fragrance compounds are prone to autoxidation, forming hydroperoxides as their primary oxidation products. Hydroperoxides are known to be strong allergens and to form specific immunogenic complexes. However, the mechanisms for the formation of the immunogenic complexes are largely unknown. We have investigated this mechanism for (5R)-5-isopropenyl-2-methyl-2-cyclohexene-1-hydroperoxide (Lim-2-OOH) by studying the formation of adducts in the reaction between this hydroperoxide and 5,10,15,20-tetraphenyl-21H,23H-porphine iron(III) chloride (Fe(III)TPPCl) in the presence of protected cysteine (NAc-Cys-OMe) or glutathione (GSH). Isolated adducts originate from the addition of the thiol group of NAc-Cys-OMe over the carbon-carbon double bonds of carvone. Furthermore, adducts between NAc-Cys-OMe and carveol as well as between GSH and carvone have been identified. The formation of these adducts most likely proceeds via the radical thiol-ene mechanism. The addition of a terpene moiety to cysteine offers an explanation of the specificity of the immune response to structurally different hydroperoxides. These results also explain the lack of cross-reactivity between carvone and Lim-2-OOH. In conclusion, we propose that immunogenic complexes of olefinic hydroperoxides can be formed via the radical thiol-ene mechanism. These complexes will be specific for the individual olefinic hydroperoxides due to the inclusion of a terpene moiety derived from the hydroperoxide.
In this work, a new technique for off-line hyphenation between CE and MALDI-MS is presented. Two closed fused-silica capillaries were connected via a silicon chip comprising an open microcanal. The EOF in the system was evaluated using mesityloxide or leucine-enkephalin as a sample and with a running buffer that rendered the analyte neutrally charged. Comparison was made between the EOF in a closed system (first capillary solely included in the electrical circuit) and in a closed-open system (first capillary and microcanal included in the electrical circuit). It was concluded that the experimental values of the EOF agreed with the theory. The influence of the capillary outer diameter on the peak dispersion was investigated using a closed-open-closed system (first capillary, microcanal and second capillary included in the electrical circuit). It was clearly seen that a capillary with 375 microm od induced considerably higher peak dispersion than a 150 microm od capillary, due to a larger liquid dead volume in the connection between the first capillary outlet and the microcanal. Mass spectrometric analysis has also been performed following CE separation runs in a closed-open-closed system with cytochrome c and lysozyme as model proteins. It was demonstrated that a signal distribution profile of the separated analytes could be recorded over a 30 mm long microcanal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.