In Fall 2020, universities saw extensive transmission of SARS-CoV-2 among their populations, threatening health of the university and surrounding communities, and viability of in-person instruction. Here we report a case study at the University of Illinois at Urbana-Champaign, where a multimodal “SHIELD: Target, Test, and Tell” program, with other non-pharmaceutical interventions, was employed to keep classrooms and laboratories open. The program included epidemiological modeling and surveillance, fast/frequent testing using a novel low-cost and scalable saliva-based RT-qPCR assay for SARS-CoV-2 that bypasses RNA extraction, called covidSHIELD, and digital tools for communication and compliance. In Fall 2020, we performed >1,000,000 covidSHIELD tests, positivity rates remained low, we had zero COVID-19-related hospitalizations or deaths amongst our university community, and mortality in the surrounding Champaign County was reduced more than 4-fold relative to expected. This case study shows that fast/frequent testing and other interventions mitigated transmission of SARS-CoV-2 at a large public university.
In the Fall of 2020, many universities saw extensive transmission of SARS-CoV-2 among their populations, threatening the health of students, faculty and staff, the viability of in-person instruction, and the health of surrounding communities.1, 2 Here we report that a multimodal “SHIELD: Target, Test, and Tell” program mitigated the spread of SARS-CoV-2 at a large public university, prevented community transmission, and allowed continuation of in-person classes amidst the pandemic. The program combines epidemiological modelling and surveillance (Target); fast and frequent testing using a novel and FDA Emergency Use Authorized low-cost and scalable saliva-based RT-qPCR assay for SARS-CoV-2 that bypasses RNA extraction, called covidSHIELD (Test); and digital tools that communicate test results, notify of potential exposures, and promote compliance with public health mandates (Tell). These elements were combined with masks, social distancing, and robust education efforts. In Fall 2020, we performed more than 1,000,000 covidSHIELD tests while keeping classrooms, laboratories, and many other university activities open. Generally, our case positivity rates remained less than 0.5%, we prevented transmission from our students to our faculty and staff, and data indicate that we had no spread in our classrooms or research laboratories. During this fall semester, we had zero COVID-19-related hospitalizations or deaths amongst our university community. We also prevented transmission from our university community to the surrounding Champaign County community. Our experience demonstrates that multimodal transmission mitigation programs can enable university communities to achieve such outcomes until widespread vaccination against COVID-19 is achieved, and provides a roadmap for how future pandemics can be addressed.
A B S T R A C TPorcine hemagglutinating encephalomyelitis virus (PHEV) is a single-stranded, positive-sense RNA virus. PHEV mainly causes two types of clinical manifestations representing vomiting and wasting and encephalomyelitis in piglets. However, our recent findings provide strong evidence that PHEV can also cause respiratory disease in older pigs. Genomic analysis of new PHEV strains identified in our former study further classifies PHEV into three genotypes. Detection and differentiation of these new mutants are critical in monitoring PHEV evolution in the field. In the present study, we report the development of a triplex real-time RT-PCR assay for detection and differentiation of three PHEV genotypes, 1, 2, and 3. Three sets of primers and probes were designed; one set of primers and probe targeting the conserved regions of the 3′ end nucleocapsid for detection of all three genotypes and another two sets of primers and probes targeting the regions of NS2 with different patterns of deletions for detection of both genotypes 1 and 3, or genotype 3 only. Genotype 1 was positive when two probe dyes showed signals, genotype 2 was positive when only one probe dye showed a signal, and genotype 3 was positive when all three probes showed signals. The detection limit of the developed triplex real-time RT-PCR was as low as 8 or 9 DNA copies for three sets of primers and probes. The specificity test showed no cross reaction with other porcine viruses. Positive field-samples were correctly typed by this new assay, which was further confirmed by DNA sequencing. The triplex real-time RT-PCR provides a rapid and sensitive method to detect and differentiate all three US genotypes of PHEV from clinical samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.