Compared with standard PS, NAVA can improve patient-ventilator synchrony in intubated spontaneously breathing intensive care patients. Further studies should aim to determine the clinical impact of this improved synchrony.
Background Little information is available about the geo-economic variations in demographics, management, and outcomes of patients with acute respiratory distress syndrome (ARDS). We aimed to characterise the effect of these geo-economic variations in patients enrolled in the Large Observational Study to Understand the Global Impact of Severe Acute Respiratory Failure (LUNG SAFE). Methods LUNG SAFE was done during 4 consecutive weeks in winter, 2014, in a convenience sample of 459 intensivecare units in 50 countries across six continents. Inclusion criteria were admission to a participating intensive-care unit (including transfers) within the enrolment window and receipt of invasive or non-invasive ventilation. One of the trial's secondary aims was to characterise variations in the demographics, management, and outcome of patients with ARDS. We used the 2016 World Bank countries classification to define three major geo-economic groupings, namely European high-income countries (Europe-High), high-income countries in the rest of the world (rWORLD-High), and middle-income countries (Middle). We compared patient outcomes across these three groupings. LUNG SAFE is registered with ClinicalTrials.gov, number NCT02010073. Findings Of the 2813 patients enrolled in LUNG SAFE who fulfilled ARDS criteria on day 1 or 2, 1521 (54%) were recruited from Europe-High, 746 (27%) from rWORLD-High, and 546 (19%) from Middle countries. We noted significant geographical variations in demographics, risk factors for ARDS, and comorbid diseases. The proportion of patients with severe ARDS or with ratios of the partial pressure of arterial oxygen (PaO 2) to the fractional concentration of oxygen in inspired air (F I O 2) less than 150 was significantly lower in rWORLD-High countries than in the two other regions. Use of prone positioning and neuromuscular blockade was significantly more common in Europe-High countries than in the other two regions. Adjusted duration of invasive mechanical ventilation and length of stay in the intensive-care unit were significantly shorter in patients in rWORLD-High countries than in Europe-High or Middle countries. High gross national income per person was associated with increased survival in ARDS; hospital survival was significantly lower in Middle countries than in Europe-High or rWORLD-High countries. Interpretation Important geo-economic differences exist in the severity, clinician recognition, and management of ARDS, and in patients' outcomes. Income per person and outcomes in ARDS are independently associated.
Purpose: To determine if, compared to pressure support (PS), neurally adjusted ventilatory assist (NAVA) reduces patient-ventilator asynchrony in intensive care patients undergoing noninvasive ventilation with an oronasal face mask. Methods: In this prospective interventional study we compared patient-ventilator synchrony between PS (with ventilator settings determined by the clinician) and NAVA (with the level set so as to obtain the same maximal airway pressure as in PS). Two 20-min recordings of airway pressure, flow and electrical activity of the diaphragm during PS and NAVA were acquired in a randomized order. Trigger delay (T d ), the patient's neural inspiratory time (T in ), ventilator pressurization duration (T iv ), inspiratory time in excess (T iex ), number of asynchrony events per minute and asynchrony index (AI) were determined. Results: The study included 13 patients, six with COPD, and two with mixed pulmonary disease. T d was reduced with NAVA: median 35 ms (IQR 31-53 ms) versus 181 ms (122-208 ms); p = 0.0002. NAVA reduced both premature and delayed cyclings in the majority of patients, but not the median T iex value. The total number of asynchrony events tended to be reduced with NAVA: 1.0 events/min (0.5-3.1 events/min) versus 4.4 events/min (0.9-12.1 events/min); p = 0.08. AI was lower with NAVA: 4.9 % (2.5-10.5 %) versus 15.8 % (5.5-49.6 %); p = 0.03. During NAVA, there were no ineffective efforts, or late or premature cyclings. PaO 2 and PaCO 2 were not different between ventilatory modes. Conclusion: Compared to PS, NAVA improved patient ventilator synchrony during noninvasive ventilation by reducing T d and AI. Moreover, with NAVA, ineffective efforts, and late and premature cyclings were absent.
BackgroundVolume-controlled ventilation has been suggested to optimize lung deposition during nebulization although promoting spontaneous ventilation is targeted to avoid ventilator-induced diaphragmatic dysfunction. Comparing topographic aerosol lung deposition during volume-controlled ventilation and spontaneous ventilation in pressure support has never been performed. The aim of this study was to compare lung deposition of a radiolabeled aerosol generated with a vibrating-mesh nebulizer during invasive mechanical ventilation, with two modes: pressure support ventilation and volume-controlled ventilation.MethodsSeventeen postoperative neurosurgery patients without pulmonary disease were randomly ventilated in pressure support or volume-controlled ventilation. Diethylenetriaminepentaacetic acid labeled with technetium-99m (2 mCi/3 mL) was administrated using a vibrating-mesh nebulizer (Aerogen Solo®, provided by Aerogen Ltd, Galway, Ireland) connected to the endotracheal tube. Pulmonary and extrapulmonary particles deposition was analyzed using planar scintigraphy.ResultsLung deposition was 10.5 ± 3.0 and 15.1 ± 5.0 % of the nominal dose during pressure support and volume-controlled ventilation, respectively (p < 0.05). Higher endotracheal tube and tracheal deposition was observed during pressure support ventilation (27.4 ± 6.6 vs. 20.7 ± 6.0 %, p < 0.05). A similar penetration index was observed for the right (p = 0.210) and the left lung (p = 0.211) with both ventilation modes. A high intersubject variability of lung deposition was observed with both modes regarding lung doses, aerosol penetration and distribution between the right and the left lung.ConclusionsIn the specific conditions of the study, volume-controlled ventilation was associated with higher lung deposition of nebulized particles as compared to pressure support ventilation. The clinical benefit of this effect warrants further studies.Clinical trial registration NCT01879488Electronic supplementary materialThe online version of this article (doi:10.1186/s13613-016-0169-x) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.