Objective The aim of this study was to describe minimally invasive spinal stabilization using a unilateral uniplanar external skeletal fixator (ESF, type 1a) with polymethylmethacrylate, and to review short- and long-term outcomes and complications in a clinical case series.
Materials and Methods Medical records from animals affected by spinal fracture luxation were reviewed. The data included breed, age, gender, body weight, aetiology, preoperative and postoperative neurological state, radiographic findings, surgical treatment, pin size, number of pins and stabilized vertebrae, intra- and postoperative complications and neurological state at re-examinations.
Results Thirty-two animals were identified; three were treated conservatively, 19 surgically and 10 were euthanatized. In eight dogs and six cats, the injured spinal column was treated with a laterally applied percutaneous type 1a ESF under fluoroscopic guidance. Positive profile end-threaded pins inserted were from 1.6/1.9 to 3.5/4.3 mm in dogs and 1.6/1.9 to 2/2.3 mm in cats and were placed into two to five vertebral bodies. At the re-examinations, the neurological status had improved in 12 animals, deteriorated in one, and was unchanged in another one. In eight cases, no complications were detected. The most common complications included erythema, exudation and pin loosening.
Conclusion The present work shows that type 1a ESF can be successfully and minimally invasively applied to fractures and luxations of the spine in dogs and cats with minimal major complications.
OBJECTIVE
To evaluate agreement in results obtained with an MRI-based grading scheme and a macroscopic observation-based grading scheme when used to assess intervertebral disk (IVD) degeneration in cats.
SAMPLE
241 MRI and 143 macroscopic images of singular IVDs in 44 client-owned cats (40 cadaveric and 4 live).
PROCEDURES
Singular images of IVDs were obtained of live cats admitted for treatment of suspected neurologic disease (MRI images of IVDs) and of cadavers of cats euthanized for reasons unrelated to spinal disease (MRI and macroscopic images of IVDs) at the Small Animal Hospital, Vetsuisse Faculty, Zurich, Switzerland, between January 12, 2015, and October 19, 2015. The IVD images were randomized and evaluated twice by 4 observers for each grading scheme. Inter- and intraobserver reliability for the grading schemes was assessed with Cohen weighted κ analysis. Agreement and correlation between results obtained with the 2 grading schemes were determined with Cohen weighted κ and Spearman correlation coefficient (ρ) analyses, respectively.
RESULTS
Inter- and intraobserver agreement between results was substantial to almost perfect (mean weighted κ, 0.66 to 0.83 and 0.71 to 0.86, respectively) for the MRI-based grading scheme and moderate to substantial (mean weighted κ, 0.42 to 0.80 and 0.65 to 0.79, respectively) for the macroscopic observation-based grading scheme. Between the 2 grading schemes, agreement in results was moderate (mean ± SE weighted κ, 0.56 ± 0.05), and the correlation was strong (ρ = 0.73).
CONCLUSIONS AND CLINICAL RELEVANCE
Results indicated that the MRI-based and macroscopic observation-based grading schemes used in the present study could be used reliably for classifying IVD degeneration in cats.
Objective: Our objectives were to report complications associated with stabilization of long-bone fractures in cats using a 3.5-mm titanium interlocking nail and to examine the influences of signalment, fracture type and fixation evaluations on the occurrence of complications.
Study Design: Retrospective clinical study.
Material and Methods: Medical and radiographic records of cats with long-bone fractures treated with an interlocking nail were reviewed. Data included age, sex, weight, cause of the fracture, fractured bone(s) and fracture type. Complications were classified as minor and major complications. Fisher's exact tests and logistic regression analysis were used to test whether certain variables of signalment and interlocking nail configuration had an effect on the occurrence of complications.
Results: Sixty-seven fractures of 67 cats were examined in this study. Forty-eight femora, sixteen tibiae and three humeri were included. Complications occurred in 11/67 fractures. Major complications occurred in 8/67 fractures and included screw breakage (n = 3), nail breakage (n = 2), nail bending (n = 1), screw loosening (n = 1), non-union (n = 1). Statistical analysis showed a significant difference between fracture types and the occurrence of major complications (p = 0.02).
Conclusion: In conclusion, use of this commercially available standard 3.5-mm titanium interlocking nail for stabilization of comminuted and oblique humeral, femoral and tibial fractures in cats is feasible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.