An assessment of the emission of combustible gases in developing countries requires reliable analytical realtime monitors that can rapidly screen them with minimal handling. Considering the expensive nature of monitoring environmental pollutants, chemical sensors are expected to play a pivotal role in measuring and recording environmental data. The Drager X am 5000 was used to report emission levels of combustible gases in this study, namely; nitrogen dioxide (NO 2 ), sulphur dioxide (SO 2 ) and carbon monoxide (CO) at traffic and practising waste dumpsite in Freetown, the main city of Sierra Leone. Hourly average values for the three pollutants were recorded in the morning, afternoon and evening periods, respectively. The range of values were 18 -76 ppb for NO 2 , 211 -506 ppb for SO 2 and 11 -14 ppm for CO at traffic site; and 6 -16 ppb for NO 2 , 118 -276 ppb for SO 2 and 8 -15 ppm for CO at the dumpsite, respectively. There were significantly high hourly variations for NO 2 and SO 2 at the traffic site and for CO and SO 2 at the dumpsite. Evidence of peak values showed emission levels that were considered dangerous for human exposure. This pilot study revealed that combustible gases released in certain areas of the capital city are a concern for both public health officials and environmental advocates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.