The objectives of this study were to investigate the structure of Invisalign appliances (Align Technology, Santa Clara, Calif) after intraoral exposure, and to qualitatively and quantitatively characterize the substances leached from the aligners after accelerated in vitro aging. Samples of Invisalign appliances were randomly selected from 10 patients before intraoral placement and after retrieval, and the prepared specimens were subjected to (1) bright-field optical reflection microscopy to study the surface morphology; (2) Fourier transform infrared microspectroscopy to characterize the in vivo changes in molecular composition induced on appliance surfaces, (3) scanning electron microscopy and energy dispersive X-ray microanalysis to identify the elemental composition of integuments formed on the surface, and (4) Vickers hardness (HV 200) testing. Another set of reference and retrieved appliances was subjected to artificial aging for 2 weeks, and the extracts were subjected to gas chromatography-mass spectroscopy. The retrieved appliances demonstrated substantial morphological variation relative to the as-received specimens involving abrasion at the cusp tips, adsorption of integuments, and localized calcification of the precipitated biofilm at stagnation sites. Buccal segments of retrieved appliances showed an increase in hardness, which might be attributed to mastication-induced cold work; however, the clinical implication of this effect on mechanotherapy is unknown. In vitro aged and retrieved appliances were found to leach no traceable amount of substances in an ethanol aging solution.
These results confirm the findings of previous studies of the effect of rapid maxillary expansion on the maxilla. Additionally, we found that only the cross-sectional area of the upper airway at the posterior nasal spine to basion level significantly gains a moderate increase after rapid maxillary expansion.
The purpose of this study was to determine the transformation temperatures for the austenitic, martensitic, and rhombohedral (R) structure phases in representative as-received commercial nitinol (NiTi) orthodontic wire alloys, to reconcile discrepancies among recent publications. Specimens were examined by differential scanning calorimetry (DSC) over a temperature range from approximately -170 degrees C to 100 degrees C, with a scanning rate of 10 degrees C per minute. Two different pathways, with the intermediate R structure either absent or present, were observed for the transformation from martensitic to austenitic NiTi, whereas the reverse transformation from austenitic to martensitic NiTi always included the R structure. The enthalpy (delta H) for the transformation from martensite to austenite ranged from 0.3 to 3.5 calories per gram. The lowest delta H value for the nonsuperelastic Nitinol wire is consistent with a largely work-hardened, stable, martensitic microstructure in this product. The DSC results indicate that the transformation processes are broadly similar in superelastic, body-temperature shape-memory, and nonsuperelastic NiTi wires. Differences in bending properties for the NiTi orthodontic wires at room temperature and 37 degrees C are due to the relative proportions of the metallurgical phases in the microstructures.
All three groups demonstrated clinically acceptable bond strength. The Damon 2 self-ligating bracket exhibited satisfactory in vitro bond strength with both adhesive systems used.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.