The results of a prospective, nonrandomized, multicenter clinical trial that compared endovascular stent graft exclusion of abdominal aortic aneurysms with open surgical repair are presented. During an 18-month period, 250 patients with infrarenal aneurysms underwent treatment at 12 study sites-190 patients underwent endovascular repair using the Medtronic AneuRx stent graft (Sunnyvale, Calif), and 60 underwent open surgical repair. There was no significant difference in operative mortality rates between the groups. The patients who underwent stent grafting had significant reductions in blood loss, time to extubation, and days in the intensive care unit and in the hospital, with an earlier return to function. The major morbidity rate was reduced from 23% in the surgery group to 12% (P <. 05) in the stent graft group. There was no difference in the combined morbidity/mortality rates between the two groups. Primary technical success at the time of discharge for the patients with stent grafts was 77%, largely as a result of a 21% endoleak rate. At 1 month, the endoleak rate had decreased to 9%. There was no difference in the primary or secondary procedure success rates at 30 days between the surgery and stent graft groups. The primary graft patency rate at 6 months was 98% in the surgery group and 97% in the stent graft group. The aneurysm exclusion rate at 1 month and 6 months was 100% in patients who underwent surgery and 91% in patients who underwent stent grafting. Stent graft migration occurred in three patients and resulted in late endoleaks; each endoleak was corrected by means of endovascular placement of a stent graft extender cuff. There have been no aneurysm ruptures and no surgical conversions to open repair in the stent graft group. Stent graft repair compares favorably with open surgical repair, with a reduced morbidity rate, shortened hospital stays, and satisfactory short term outcomes.
Stent-graft migration among patients treated in the AneuRx clinical trial appears to be largely related to low initial deployment of the device, below the renal arteries, and short proximal fixation length. Significant variation in migration rate among clinical sites highlights the importance of the technical aspects of stent-graft deployment. Advances in intraoperative imaging and deployment techniques that have been made since completion of the clinical trial facilitate precision of device placement below the renal arteries and should increase proximal fixation length. Whether this, together with increased iliac fixation length, will result in lower risk for migration remains to be determined in long-term follow-up studies.
These early results support the hypothesis that endovascular stent-graft placement may be a safe and durable treatment for selected patients with aneurysmal disease of the descending thoracic aorta. Large introducer size (26F outer diameter) and relatively limited angulation capability, as well as imprecise deployment techniques, currently limit its applicability. Distal embolization and stent migration have not been observed. Failure to achieve complete aneurysmal thrombosis may allow continued aneurysmal expansion and rupture. Further follow-up is clearly necessary to evaluate the true long-term effectiveness of this procedure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.