At low copy number, sequence detection by polymerase chain reaction (PCR) requires up to 30 cycles (amplification 109) to produce a reliably detectable concentration of fluorescently-labelled amplicons. The cycle number and hence detection time is determined by the analytical sensitivity of the detector. Hybridisation of complementary DNA strands to oligonucleotide-modified conducting polymer electrodes yields an increase in the charge transfer resistance for the ferri-ferrocyanide redox couple. We demonstrate sensors using screen-printed carbon electrodes modified with a conducting polymer formed from a monomer pre-functionalised with complementary oligonucleotide, with pM sensitivity for short sequences and aM for bacterial lysate, with a response time-scale of 5 min. The response is due to the variation of electrical resistance within the polymer film. We develop a mechanism based on repulsion from the solution interface of dopant anions by the charge associated with surface-bound DNA. With results for >160 single-use sensors, we formulate a response model based on percolation within a random resistor network and highlight challenges for large-scale manufacture of such sensors. Such sensors used for label-free electrochemical detection for PCR (e-PCR) would decrease the required cycle number from 30 to less than 10 and would offer a much simplified instrument construction.
At low copy number, sequence detection by polymerase chain reaction (PCR) requires up to 30 cycles (amplification by a factor of 109) to produce a reliably detectable concentration of fluorescently-labelled amplicons. The cycle number and hence detection time is determined by the analytical sensitivity of the detector. Hybridisation of complementary DNA strands to oligonucleotide-modified conducting polymer electrodes yields an increase in the charge transfer resistance for the ferri-ferrocyanide redox couple. Sensors using this technology for e-PCR offer a label-free method with detector sensitivity in the pM range, potentially decreasing the required cycle number from 30 to 10 and offering a much simplified instrument construction. We demonstrate sensors using screen-printed carbon electrodes modified with a conducting polymer formed from a monomer pre-functionalised with complementary oligonucleotide. Off-chip pre-functionalisation of the conducting polymer precursor is a key step towards practical manufacture and the method is potentially a general one for sensors which require a capture probe-functionalised surface. We demonstrate reliable sensitivity of the interfacial resistance change at the pM scale for short (20-mer) sequences and at the aM scale for bacterial lysate, with dynamic range extending to μM scale and response time-scale 5 min. Donnan exclusion of the redox couple from the surface, as previously proposed, seems unlikely as a mechanism for such ultra-high sensitivity. We demonstrate that the most important element in the response at the lowest concentrations is due to variation of an electrical resistance within the polymer film. We develop a mechanism based on repulsion from the solution interface of dopant anions and attraction towards and trapping at the interface of radical cations (polarons) by the charge associated with surface-bound DNA. With results for >160 single-use sensors, we formulate a response model based on percolation within a random resistor network and highlight challenges for large-scale manufacture of such sensors. We propose a PCR device concept for rapid use at point-of-sampling.
At low copy number, sequence detection by polymerase chain reaction (PCR) requires up to 30 cycles (amplification by a factor of 109) to produce a reliably detectable concentration of fluorescently-labelled amplicons. The cycle number and hence detection time is determined by the analytical sensitivity of the detector. Hybridisation of complementary DNA strands to oligonucleotide-modified conducting polymer electrodes yields an increase in the charge transfer resistance for the ferri-ferrocyanide redox couple. Sensors using this technology for e-PCR offer a label-free method with detector sensitivity in the pM range, potentially decreasing the required cycle number from 30 to 10 and offering a much simplified instrument construction. We demonstrate sensors using screen-printed carbon electrodes modified with a conducting polymer formed from a monomer pre-functionalised with complementary oligonucleotide. Off-chip pre-functionalisation of the conducting polymer precursor is a key step towards practical manufacture and the method is potentially a general one for sensors which require a capture probe-functionalised surface. We demonstrate reliable sensitivity of the interfacial resistance change at the pM scale for short (20-mer) sequences and at the aM scale for bacterial lysate, with dynamic range extending to μM scale and response time-scale 5 min. Donnan exclusion of the redox couple from the surface, as previously proposed, seems unlikely as a mechanism for such ultra-high sensitivity. We demonstrate that the most important element in the response at the lowest concentrations is due to variation of an electrical resistance within the polymer film. We develop a mechanism based on repulsion from the solution interface of dopant anions and attraction towards and trapping at the interface of radical cations (polarons) by the charge associated with surface-bound DNA. With results for >160 single-use sensors, we formulate a response model based on percolation within a random resistor network and highlight challenges for large-scale manufacture of such sensors. We propose a PCR device concept for rapid use at point-of-sampling.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.