The transverse loading requirement for stoppings as specified in the current Code of Federal Regulations is 39 psf. This measure is based on physical testing of a freestanding wall in accordance with ASTM E 72 specifications, where the dominant parameter is the tensile strength of the sealant. A new protocol based on rigid arching is proposed to determine the true transverse load capacity of stoppings. Arching is achieved by the restraint of the stopping against the mine roof and floor, whereby compressive forces are developed within the wall. A laboratory procedure using the NIOSH Mine Roof Simulator (MRS) to simulate rigid-arching of stoppings was developed and verified through full-scale in-mine tests. The rigid arching tests have demonstrated transverse load capacities more than an order of magnitude higher than the current 39-psf requirement. More importantly, the load capability is dependent on the physical properties of the block and not the sealant. vi
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.