Engineered cartilage is a promising option for auricular reconstruction. We have previously demonstrated that a titanium wire framework within a composite collagen ear-shaped scaffold helped to maintain the gross dimensions of the engineered ear after implantation, resisting the deformation forces encountered during neocartilage maturation and wound healing. The ear geometry was redesigned to achieve a more accurate aesthetic result when implanted subcutaneously in a nude rat model. A non-invasive method was developed to assess size and shape changes of the engineered ear in three dimensions. Computer models of the titanium framework were obtained from CT scans before and after implantation
.
Several parameters were measured including the overall length, width and depth, the minimum intrahelical distance and overall curvature values for each beam section within the framework. Local curvature values were measured to gain understanding of the bending forces experienced by the framework structure
in situ
. Length and width changed by less than 2%, whereas the depth decreased by approximately 8% and the minimum intrahelical distance changed by approximately 12%. Overall curvature changes identified regions most susceptible to deformation. Eighty-nine per cent of local curvature measurements experienced a bending moment less than 50 µN-m owing to deformation forces during implantation. These quantitative shape analysis results have identified opportunities to improve shape fidelity of engineered ear constructs.
Advancement of engineered ear in clinical practice is limited by several challenges. The complex, largely unsupported, three-dimensional auricular neocartilage structure is difficult to maintain. Neocartilage formation is challenging in an immunocompetent host due to active inflammatory and immunological responses. The large number of autologous chondrogenic cells required for engineering an adult human-sized ear presents an additional challenge because primary chondrocytes rapidly dedifferentiate during in vitro culture. The objective of this study was to engineer a stable, human ear-shaped cartilage in an immunocompetent animal model using expanded chondrocytes. The impact of basic fibroblast growth factor (bFGF) supplementation on achieving clinically relevant expansion of primary sheep chondrocytes by in vitro culture was determined. Chondrocytes expanded in standard medium were either combined with cryopreserved, primary passage 0 chondrocytes at the time of scaffold seeding or used alone as control. Disk and human ear-shaped scaffolds were made from porous collagen; ear scaffolds had an embedded, supporting titanium wire framework. Autologous chondrocyte-seeded scaffolds were implanted subcutaneously in sheep after 2 weeks of in vitro incubation. The quality of the resulting neocartilage and its stability and retention of the original ear size and shape were evaluated at 6, 12, and 20 weeks postimplantation. Neocartilage produced from chondrocytes that were expanded in the presence of bFGF was superior, and its quality improved with increased implantation time. In addition to characteristic morphological cartilage features, its glycosaminoglycan content was high and marked elastin fiber formation was present. The overall shape of engineered ears was preserved at 20 weeks postimplantation, and the dimensional changes did not exceed 10%. The wire frame within the engineered ear was able to withstand mechanical forces during wound healing and neocartilage maturation and prevented shrinkage and distortion. This is the first demonstration of a stable, ear-shaped elastic cartilage engineered from auricular chondrocytes that underwent clinical-scale expansion in an immunocompetent animal over an extended period of time.
A versatile solvent-free method for surface modification of various materials including both metals and polymers is described. Strong irreversible bonds were formed when substrates modified by initiated chemical vapor deposition (iCVD) of poly(1,3,5-trivinyltrimethylcyclotrisiloxane) or poly(V3D3) and exposed to an oxygen plasma were brought into contact with plasma-treated poly(dimethylsiloxane) (PDMS). The strength of these bonds was quantified by burst pressure testing microfluidic channels in the PDMS. The burst pressures of PDMS bonded to various coated substrates were in some cases comparable to that of PDMS bonded directly to PDMS. In addition, porous PTFE membrane coated with poly(V3D3) was successfully bonded to a PDMS microfluidic device and withstood pressures of over 300 mmHg. Bond strength was shown to correlate with surface roughness and quality of the bond between the coating and substrate. This work paves a methodology to fabricate microfluidic devices that include a specifically tailored membrane. Furthermore, the bonded devices exhibited hydrolytic stability; no dramatic change was observed even after immersion in water at room temperature over a period of 10 days.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.