Objective/Background Historically, the sole option for patients with a dysfunctional native right ventricular outflow tract (RVOT) requiring re-establishment of pulmonary competence has been surgical PVR. We sought to compare early outcomes of hybrid pulmonary valve replacement (PVR) combining surgical plication of the main pulmonary artery followed by transcatheter PVR, with a contemporary cohort of surgical PVR patients. Methods Retrospective chart analysis of all patients with a dilated native RVOT eligible for surgical PVR over 36 months was performed. The cohorts included patients with previous tetralogy of Fallot repair (n = 14), and previous intervention for congenital abnormality of the pulmonary valve (n = 7). Results Twenty-one patients with a dysfunctional native RVOT met criteria for PVR; 8 using the hybrid procedure (group 1: age, 31.5 +/- 17.4 years) and 13 with cardiopulmonary bypass (CPB) (group 2: age, 31 +/- 18.4 years). Valve delivery was successful in all patients with no procedural mortality. Group 1 had a lesser requirement for blood products (P =< 0.001) and a trend toward shorter hospital stay and higher post-operative hemoglobin. No patients in group 1 received inotropic support post-operatively compared to 54% of patients in group 2. Mean follow-up was 3.4 months for group 1 and 13.6 months for group 2 with the average peak gradient across the RVOT of 20.1 and 15.1 mm Hg respectively (P = 0.12), all with no more than mild PI. Conclusions Transcatheter hybrid PVR following RVOT plication provides a reasonable alternative to surgical PVR particularly in higher risk cohorts, reducing possible longer-term consequences of repeated runs of CPB. © 2016 Wiley Periodicals, Inc.
Background: Polymer-based bioresorbable scaffolds (PBBS) have been assessed for coronary revascularization with mixed outcomes. Few studies have targeted pediatric-specific scaffolds. We sought to assess safety, efficacy, and short-term performance of a dedicated drug-free PBBS pediatric scaffold compared to a standard low-profile bare metal stent (BMS) in central and peripheral arteries of weaned piglets. Methods: Forty-two devices (22 Elixir poly-L-lactic-acid-based pediatric bioresorbable scaffolds [BRS] [6 × 18 mm] and 20 control BMS Cook Formula 418 [6 × 20 mm]) were implanted in the descending aorta and pulmonary arteries (PAs) of 14 female Yucatan piglets. Quantitative measurements were collected on the day of device deployment and 30 and 90 days postimplantation to compare device patency and integrity. Results: The BRS has a comparable safety profile to the BMS in the acute setting. Late lumen loss (LLL) and percent diameter stenosis (%DS) were not significantly different between BRS and BMS in the PA at 30 days. LLL and %DS were greater for BRS versus BMS in the aorta at 30 days postimplantation (LLL difference: 0.96 ± 0.26; %DS difference: 16.15 ± 4.51; p < .05). At 90 days, %DS in the aortic BRS was less, and PA BRS LLL was also less than BMS. Histomorphometric data showed greater intimal proliferation and area stenosis in the BRS at all time points and in all vessels. Conclusions: A dedicated PBBS pediatric BRS has a favorable safety profile in the acute/subacute setting and demonstrates characteristics that are consistent with adult BRSs.
Background: Covered stents are widely used outside of the United States to treat adult patients with congenital heart disease. However, these stents have not been approved by the United States Food and Drug Administration (FDA). We describe our experience with large diameter, self-fabricated covered stents for patients with congenital heart disease. Methods: We retrospectively examined results of adults with congenital heart disease who received a selfdesigned covered stent at our institution. We detailed our method of fabricating the covered stent and modifications in delivery to minimize traction or trauma against the outer covering of the stent. Conclusions: Our self-fabricated covered stents were safe and provided effective gradient reduction or intraluminal continuity to treat individualized lesions related to congenital heart disease. Covered stents increase the therapeutic options for the interventional cardiologist and in some cases may be safer for the patient. There needs to be increased pressure from providers towards the FDA to approve these stents in the United States.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.