Ultrasound (US) scanners typically apply lossy, non-linear modifications to the US data for visualization purposes. The resulting images are then stored as compressed video data. Some system manufacturers provide dedicated software for quantification purposes to eliminate such processing distortions, at least partially. This is currently the recommended approach for quantitatively assessing changes in contrast-agent concentration from clinical data. However, the machine-specific access to US data and the limited set of analysis functionalities offered by each dedicated-software package make it difficult to perform comparable analyses with different US systems. The objective of this work was to establish if linearization of compressed video images obtained with an arbitrary US system can provide an alternative to dedicated-software analysis of machine-specific files for the estimation of echo-power. For this purpose, an Aplio 50 system (Toshiba Medical Systems, Tochigi, Japan), coupled with dedicated CHI-Q (Contrast Harmonic Imaging Quantification) software by Toshiba Medical Systems, was used. Results were compared with two approaches that apply algorithms to estimate relative echo-power from compressed video images: commercially available VueBox software by Bracco Suisse SA (Geneva, Switzerland) and in-laboratory software called PixPower. The echo-power estimated by CHI-Q analysis indicated a strong linear relationship versus agent concentration in vitro (R(2) ≥ 0.9996) for dynamic range (DR) settings of DR60 and DR80, with slopes between 9.22 and 9.57 dB/decade (p = 0.05). These values approach the theoretically predicted dependence of 10.0 dB/decade (equivalent to 3 dB for each concentration doubling). Echo-power estimations obtained from compressed video images with VueBox and PixPower also exhibited strong linear proportionality with concentration (R(2) ≥ 0.9996), with slopes between 9.30 and 9.68 dB/decade (p = 0.05). On an independent in vivo data set (N = 24), the difference in echo-power estimation between CHI-Q and each of the other two approaches was calculated after excluding regions that contain pixels affected by saturated or thresholded pixel values. The mean difference in estimates (expressed in decibels) was -0.25 dB between VueBox and CHI-Q (95% confidence interval: -0.75 to 0.26 dB) and -0.17 dB between PixPower and CHI-Q (95% confidence interval: -0.67 to 0.13 dB). To achieve linearization of data, one of the approaches (VueBox) requires calibration files provided by the software manufacturer for each machine type and setting. The other (PixPower) requires empirical correction of the imaging dynamic range based on ground truth data. These requirements could potentially be removed if US system manufacturers were willing to make relevant information on the applied processing publically available. Reliable echo-power estimation from linearized data would facilitate inclusion of different US systems in multicentric studies and more widespread implementation of emerging techniques for quantitative ...
Purpose: Pancreatic ductal adenocarcinoma (PDA) is a common, deadly cancer that is challenging both to diagnose and to manage. Its hallmark is an expansive, desmoplastic stroma characterized by high mechanical stiffness. In this study, we sought to leverage this feature of PDA for two purposes: differential diagnosis and monitoring of response to treatment. Experimental Design: Harmonic motion imaging (HMI) is a functional ultrasound technique that yields a quantitative relative measurement of stiffness suitable for comparisons between individuals and over time. We used HMI to quantify pancreatic stiffness in mouse models of pancreatitis and PDA as well as in a series of freshly resected human pancreatic cancer specimens. Results: In mice, we learned that stiffness increased during progression from preneoplasia to adenocarcinoma and also effectively distinguished PDA from several forms of pancreatitis. In human specimens, the distinction of tumors versus adjacent pancreatitis or normal pancreas tissue was even more stark. Moreover, in both mice and humans, stiffness increased in proportion to tumor size, indicating that tuning of mechanical stiffness is an ongoing process during tumor progression. Finally, using a brca2–mutant mouse model of PDA that is sensitive to cisplatin, we found that tissue stiffness decreases when tumors respond successfully to chemotherapy. Consistent with this observation, we found that tumor tissues from patients who had undergone neoadjuvant therapy were less stiff than those of untreated patients. Conclusions: These findings support further development of HMI for clinical applications in disease staging and treatment response assessment in PDA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.