We present a sensing system operating at millimetre (mm) waves in transmission mode that can measure glucose level changes based on the complex permittivity changes across the signal path. The permittivity of a sample can change significantly as the concentration of one of its substances varies: for example, blood permittivity depends on the blood glucose levels. The proposed sensing system uses two facing microstrip patch antennas operating at 60 GHz, which are placed across interrogated samples. The measured transmission coefficient depends on the permittivity change along the signal path, which can be correlated to the change in concentration of a substance. Along with theoretical estimations, we experimentally demonstrate the sensing performance of the system using controlled laboratory samples, such as water-based glucose-loaded liquid samples. We also present results of successful glucose spike detection in humans during an in-vivo Intravenous Glucose Tolerance Test (IVGTT). The system could eventually be developed into a non-invasive glucose monitor for continuous monitoring of glucose levels for people living with diabetes, as it can detect as small as 1.33 mmol/l (0.025 wt%) glucose concentrations in the controlled water-based samples satisfactorily, which is well below the typical human glucose levels of 4 mmol/l.
Purpose To investigate the effects of 60 min daily, short-term (STHA) and medium-term (MTHA) isothermic heat acclimation (HA) on the physiological and perceptual responses to exercise heat stress. Methods Sixteen, ultra-endurance runners (female = 3) visited the laboratory on 13 occasions. A 45 min sub-maximal (40% W max) cycling heat stress test (HST) was completed in the heat (40 °C, 50% relative humidity) on the first (HST PRE), seventh (HST STHA) and thirteenth (HST MTHA) visit. Participants completed 5 consecutive days of a 60 min isothermic HA protocol (target T re 38.5 °C) between HST PRE and HST STHA and 5 more between HST STHA and HST MTHA. Heart rate (HR), rectal (T re), skin (T sk) and mean body temperature (T body), perceived exertion (RPE), thermal comfort (TC) and sensation (TS) were recorded every 5 min. During HSTs, cortisol was measured pre and post and expired air was collected at 15, 30 and 45 min. Results At rest, T re and T body were lower in HST STHA and HST MTHA compared to HST PRE, but resting HR was not different between trials. Mean exercising T re , T sk , T body , and HR were lower in both HST STHA and HST MTHA compared to HST PRE. There were no differences between HST STHA and HST MTHA. Perceptual measurements were lowered by HA and further reduced during HST MTHA. Conclusion A 60 min a day isothermic STHA was successful at reducing physiological and perceptual strain experienced when exercising in the heat; however, MTHA offered a more complete adaptation.
Purpose: To investigate the effects of short-term, high-intensity interval-training (HIIT) heat acclimation (HA). Methods: Male cyclists/triathletes were assigned into either an HA (n = 13) or a comparison (COMP, n = 10) group. HA completed 3 cycling heat stress tests (HSTs) to exhaustion (60% Wmax; HST1, pre-HA; HST2, post-HA; HST3, 7 d post-HA). HA consisted of 30-min bouts of HIIT cycling (6 min at 50% Wmax, then 12 × 1-min 100%-Wmax bouts with 1-min rests between bouts) on 5 consecutive days. COMP completed HST1 and HST2 only. HST and HA trials were conducted in 35°C/50% relative humidity. Cycling capacity and physiological and perceptual data were recorded. Results: Cycling capacity was impaired after HIIT HA (77.2 [34.2] min vs 56.2 [24.4] min, P = .03) and did not return to baseline after 7 d of no HA (59.2 [37.4] min). Capacity in HST1 and HST2 was similar in COMP (43.5 [8.3] min vs 46.8 [15.7] min, P = .54). HIIT HA lowered resting rectal (37.0°C [0.3°C] vs 36.8°C [0.2°C], P = .05) and body temperature (36.0°C [0.3°C] vs 35.8°C [0.3°C], P = .03) in HST2 compared with HST1 and lowered mean skin temperature (35.4°C [0.5°C] vs 35.1°C [0.3°C], P = .02) and perceived strain on day 5 compared with day 1 of HA. All other data were unaffected. Conclusions: Cycling capacity was impaired in the heat after 5 d of consecutive HIIT HA despite some heat adaptation. Based on data, this approach is not recommended for athletes preparing to compete in the heat; however, it is possible that it may be beneficial if a state of overreaching is avoided.
Purpose This study investigated the effects of acute hyperthermia and heat acclimation (HA) on maximal and rapid voluntary torque production, and their neuromuscular determinants. Methods Ten participants completed 10 days of isothermic HA (50 °C, 50% rh) and had their knee-extensor neuromuscular function assessed in normothermic and hyperthermic conditions, pre-, after 5 and after 10 days of HA. Electrically evoked twitch and octet (300 Hz) contractions were delivered at rest. Maximum voluntary torque (MVT), surface electromyography (EMG) normalised to maximal M-wave, and voluntary activation (VA) were assessed during brief maximal isometric voluntary contractions. Rate of torque development (RTD) and normalised EMG were measured during rapid voluntary contractions. Results Acute hyperthermia reduced neural drive (EMG at MVT and during rapid voluntary contractions; P < 0.05), increased evoked torques (P < 0.05), and shortened contraction and relaxation rates (P < 0.05). HA lowered resting rectal temperature and heart rate after 10 days (P < 0.05), and increased sweating rate after 5 and 10 days (P < 0.05), no differences were observed between 5 and 10 days. The hyperthermia-induced reduction in twitch half-relaxation was attenuated after 5 and 10 days of HA, but there were no other effects on neuromuscular function either in normothermic or hyperthermic conditions. Conclusion HA-induced favourable adaptations to the heat after 5 and 10 days of exposure, but there was no measurable benefit on voluntary neuromuscular function in normothermic or hyperthermic conditions. HA did reduce the hyperthermic-induced reduction in twitch half-relaxation time, which may benefit twitch force summation and thus help preserve voluntary torque in hot environmental conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.