In an analysis of data from real-life clinical practice, we associated infliximab concentrations during the induction therapy with STMH in patients with UC.
Background and Aims: Golimumab has been approved recently to treat refractory moderate-tosevere ulcerative colitis [UC]. To date it is not clear why a considerable fraction of patients do not respond, or lose initial response, to golimumab therapy. Our aim was to investigate whether a low golimumab serum concentration and/or a positive anti-golimumab antibody status reduces the efficacy of this drug in patients with UC. Methods: Serum samples of 21 patients with moderate-to-severe UC were collected during the first 14 weeks of golimumab therapy. For measurement of golimumab serum concentrations, both a tumour necrosis factor [TNF]-coated enzyme-linked immunosorbent assay [ELISA] and a sandwich-type ELISA were developed. Anti-golimumab antibodies were measured using a bridging ELISA and a newly-developed drug-tolerant immunoassay. Clinical response and mucosal healing were assessed 14 weeks after start of treatment. Results Out of 21 patients, 10 [48%] reached partial clinical response at Week 14. Median [interquartile range] serum golimumab concentration was significantly higher in partial clinical responders than in non
Monitoring the concentration of a therapeutic drug antibody, infliximab (IFX), is recommended for enhancing its efficacy in patients with inflammatory bowel disease (IBD). However, IFX concentrations are currently determined in patients' serum/plasma, which requires sample preparation from blood, hence hampering the turnaround time. In this paper, we present a short immunoassay (10 min) using a fiber-optic surface plasmon resonance (FO-SPR) biosensor for detection of IFX spiked in 100-fold diluted serum, plasma, and whole blood. The calculated limits of detection (LOD) based on calibration curves were 1.42, 1.00, and 1.34 ng/mL, respectively, which coincides with expected IFX concentrations in diluted samples from IBD patients. A linear correlation was established among different matrixes, indicating that the matrix effect was insignificant. The established point-of-care (POC) FO-SPR bioassay was also used to measure IFX in 100-fold diluted extracts of dried blood spots (DBS), and LOD achieved was below 2 ng/mL. Although DBS might be ideal for POC, this is the first report of using an SPR biosensor for measuring DBS samples. Finally, the POC FO-SPR immunoassay was validated by using matching serum and plasma samples from five IBD patients. A Pearson correlation of 0.968 was obtained between serum and plasma samples. IFX concentrations determined with FO-SPR were compared to a clinically validated enzyme-linked immunosorbent assay (ELISA), resulting in excellent Pearson correlation and intraclass correlation coefficient, both being 0.99 for serum and plasma samples. In conclusion, this paper demonstrates that our FO-SPR biosensor can be used as a true POC diagnostic tool for determining IFX concentrations in a variety of matrixes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.