ABSTRACTObjective: The supply and distribution of mechanical ventilation capacity is of profound importance for planning for severe public health emergencies. However, the capability of US health systems to provide mechanical ventilation for children and adults remains poorly quantified. The objective of this study was to determine the quantity of adult and pediatric mechanical ventilators at US acute care hospitals.Methods: A total of 5752 US acute care hospitals included in the 2007 American Hospital Association database were surveyed. We measured the quantities of mechanical ventilators and their features.Results: Responding to the survey were 4305 (74.8%) hospitals, which accounted for 83.8% of US intensive care unit beds. Of the 52 118 full-feature mechanical ventilators owned by respondent hospitals, 24 204 (46.4%) are pediatric/neonatal capable. Accounting for nonrespondents, we estimate that there are 62 188 full-feature mechanical ventilators owned by US acute care hospitals. The median number of full-feature mechanical ventilators per 100 000 population for individual states is 19.7 (interquartile ratio 17.2–23.1), ranging from 11.9 to 77.6. The median number of pediatric-capable device full-feature mechanical ventilators per 100 000 population younger than 14 years old is 52.3 (interquartile ratio 43.1–63.9) and the range across states is 22.1 to 206.2. In addition, respondent hospitals reported owning 82 755 ventilators other than full-feature mechanical ventilators; we estimate that there are 98 738 devices other than full-feature ventilators at all of the US acute care hospitals.Conclusions: The number of mechanical ventilators per US population exceeds those reported by other developed countries, but there is wide variation across states in the population-adjusted supply. There are considerably more pediatric-capable ventilators than there are for adults only on a population-adjusted basis.(Disaster Med Public Health Preparedness. 2010;4:199-206)
The redox polymer [O~(bipy)~(P~TP),~CllCl, where bipy is 2,2'-bipyridyl and PLT is poly-4-vinylpyridine, has been physically stabilized by chemical cross-linking at various levels via the solid-state reaction with the cross-linking agents p-dibromobenzene, 1 ,j-dibromopentane, and 1 ,lo-dibromodecane. The stability of the resulting polymer films under the severe hydrodynamic conditions of thin-layer flow cells and at rotating disk electrodes (RDEs) was greatly increased compared to the uncross-linked polymer. The charge transport properties of the redox polymer were maintained or improved by cross-linking. The surface and Nernstian behavior of the cross-linked redox materials are not found to be substantially affected by cross-linking.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.