The COVID-19 pandemic is a devastating catastrophe to the whole world, China is the first country seriously affected. This review shows that it is possible to stop wide-spread infection in the country and to provide good quality oncology services even during this challenging period, through concerted efforts with well-organized actions at all levels (National/Municipal, Hospital and Department). The key strategies leading to successful impacts are summarized for sharing. In addition to making practice changes to cope with the adverse realities, oncologists should also work together to raise pragmatic suggestions to policy makers and be strong advocates to protect our patients from the detrimental effect of delay or compromised treatment.
Background and purpose: To introduce a standard linac with true attachment free, rapid arc and dose-drop scheme for positioning related dose deviation control based total body irradiation(TBI).Materials/Methods: One eight years old girl diagnosed with acute lymphocytic leukemia underwent TBI in 2020. Target volumes and organs at risk were contoured after CT simulation. Total sixteen ARC and four AP-PA from five isocenters were designed. A dose-drop scheme on both sides of adjacent region were performed to reduce positioning-related dose deviation. A series of quality assurance before radiotherapy and real-time dose monitoring during radiotherapy were carried out.Results: The average on board imaging (OBI) time of per fraction was 40.3 min, the average beam on time of per fraction was 37.2 min, the average time to change from head first to feet first position was 18.4 min. The average mean lung dose was 9.89 Gy, the maximum lens dose was 7.60 Gy, the mean PTV_total dose was 12.17Gy, 98.23% PTV_total volume was covered by 90% of the prescription dose. The maximum dose (Dmax) of PTV_total was 13.65Gy. Dmean and V10.8 of PTV_total are only slightly different(0.49% - 1.89% and 0.26% - 1.04% respectively) even with an error of 5 - 20mm longitudinal misalignments. Gamma passing rate(3mm/ 3% Gamma criteria) are between 93.5% and 100%. Real-time dose monitoring showed an overall deviation of -3.9%±5.51%.Conclusions: Standard linac, rapid arc and dose-drop for positioning-related dose deviation control based total body irradiation is feasible, accurate, and reliable. It is worthy of clinical application.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.