SUMMARYThe implantable cardioverter defibrillator (ICD) has proved effective in preventing sudden death and decreasing mortality in randomised secondary prevention trials. Some nonrandomised studies have reported different incidences and predictors of appropriate ICD therapy in patients with idiopathic dilated cardiomyopathy (DCM). The antiarrhythmic and other medical therapies were different between the published studies and it was reported that not using beta-blockers was a predictor of appropriate ICD therapy. In the present study, we report on our long-term experience with ICD therapy in patients with DCM, the majority of whom were treated with beta-blockers and amiodarone.The study population consisted of 25 patients with DCM who underwent initial transvenous ICD implantation between December 1995 and May 2005. Indications for ICD implantation were monomorphic sustained ventricular tachycardia (VT) in 16 patients (64%), cardiac arrest in 8 patients (32%), and syncope plus inducible VT in one patient. Twenty-four patients underwent an electrophysiologic study (EPS). In 18 patients, the ICDs were programmed to only shocks and in 7 patients an additional antitachycardia pacing program was performed. One patient was lost to follow-up and 24 patients were followed-up primarily in our ICD pacemaker outpatient clinic. Appropriate ICD therapy was defined as antitachycardia pacing therapy or shock for tachyarrhythmia determined by evaluation of the clinical information and by device diagnostics to be either ventricular fibrillation or ventricular tachycardia.The mean follow-up was 39.29 ± 30.59 months after ICD implantation. At follow-up, 17 patients were using a beta-blocker and 16 patients amiodarone. Appropriate ICD therapy was observed in 14 patients (58%). The detected arrhythmias were VT in 12 patients, ventricular fibrillation (VF) in one, and VT and VF in one patient. The time to first ICD therapy was 15.93 ± 18.45 (range, 1-74) months. Using the Kaplan-Meier method, the percent survival free of appropriate ICD therapy was 82%, 72%, 66%, and 55% at 1, 2, 3, and 4 years follow-up, respectively. The clinical, echocardiographic, and electrophysiologic characteristics did not differ between those who did and did not receive appropriate ICD therapy. However, the mean QRS duration was significantly longer in patients who received appropriate ICD therapies. Cox regression analysis did not reveal any factors that predicted appropriate ICD therapy. Five patients (21%) died during follow-up. FourFrom the
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.