Demographic and biological data were collected from all Caucasian Type 1 diabetic patients (n = 279) who were recruited at clinical onset by the Belgian Diabetes Registry over 34 months. The male/female ratio was significantly higher for onset between age 20 and 40 years (2.4) than before age 20 years (1.0); no age-or sex-differences were noticed in serum fructosamine concentration. Total and high concentrations of insulin autoantibodies and islet cell antibodies were preferentially associated with the HLA DQA1*0301-DQB1*0302 susceptibility haplotype. The occurrence of both types of antibodies was also correlated, irrespective of haplotype. At onset before age 10 years, the high risk genotype DQA1*0301-DQB1*0302/DQA1*0501-DQB1*0201 was more prevalent than all other DQA1-DQB1 genotypes taken together, leading to a higher prevalence of the DQA1*0301-DQB1*0302 haplotype in this age group (75%) than in the 10-39 years age group (54%). Under age 10 years, the presence of DQA1*0301-DQB1*0302 was strongly associated with insulin autoantibodies (90%) and islet cell autoantibodies (92% with 85% of high titre), whereas patients without this haplotype were less frequently positive for insulin autoantibodies (31%) or islet cell autoantibodies (38% high titre). In the group with onset at age 10-39 years, the DQA1*0301-DQB1*0302 haplotype presented a lower association with insulin autoantibodies (approximately 40%) and islet cell autoantibodies (50 to 65% high titre), prevalences which no longer differed from those in subjects lacking this haplotype.(ABSTRACT TRUNCATED AT 250 WORDS)
We describe two patients in whom chronic radiodermatitis with therapy-resistant ulceration of the right scapular region developed, following percutaneous coronary intervention with fluoroscopic imaging. Contrary to most reported cases in the literature, which involve numerous cardiac catheterization procedures, in both patients described here the total radiation dose was given during two successive procedures, involving difficult and prolonged coronary intervention with stent implantation. In both cases, local treatment of the ulcerative lesions was insufficient, necessitating excision of the radiodermatitis area and replacement with a skin graft, with good therapeutic result. The incidence of radiodermatitis after percutaneous coronary interventions is rising with the increasing number and complexity of these procedures. The main risk factor is a long duration of fluoroscopy using the same incidence. The skin lesions encompass a wide spectrum, ranging from erythema, telangiectasia, atrophy, hyperpigmentation and hypopigmentation to necrosis, chronic ulceration and squamous cell carcinoma. The lesions can appear from 15 days to 10 years after the procedure. To prevent radiation-induced injury, the radiation dose has to be limited and monitored. Also, careful inspection of the skin at the site of exposure is necessary and the radiographic beam has to be restricted to the smallest field size. A good clinical follow-up at regular intervals is important after long and complicated procedures.
At comparable doses of cisapride and comparable plasma concentrations, the QTc was significantly higher in infants younger than 3 months of age. This confirms age-dependent cisapride pharmacokinetics in the first 10 to 12 weeks strongly correlated with changes in body weight and may also suggest an altered ability of infants younger than 3 months of age to metabolize cisapride. The clinical significance and risk of the increased QTc interval is unclear. Cisapride should be judiciously prescribed in infants younger than the age of 3 months and electrocardiography should be performed before and during therapy.
ABSTRACT. Objective. To evaluate the effects of cisapride, a prokinetic gastrointestinal drug, on the electrocardiographic QT interval, heart rate, and rhythm in infants during routine 8-hour polysomnography. Reported electrocardiogram (ECG) and rhythm disturbances in a small number of patients with the use of cisapride provided the impetus for this prospective study.Study Design. Two hundred fifty-two infants born at term were enrolled. Of these, 134 were on cisapride therapy for suspected gastroesophageal reflux and 118 were not on cisapride and served as controls. Cisapride-treated and control infants were from the outset divided into 3 age groups; group 1: under 3 months of age; group 2: between 3 and 6 months of age; and group 3: >6 months of age. Continuous ECG bipolar limb lead I recording, saturation monitoring, and electroencephalography were conducted. QT intervals and heart rate were measured at hourly intervals.Results. Cisapride doses were: group 1 mean, 0.80 mg/kg/day (range: 0.38 -1.55); group 2 mean, 0.80 mg/kg/ day (range: 0.23-1.38); and group 3 mean, 0.72 mg/kg/day (range: 0.32-1.41). Heart rate was higher in the younger infants, with a gradual decrease with age. No difference in heart rate was detected between the cisapride and control groups. The QTc interval in patients in group 1 was statistically longer than the controls, when applying both Bazett's and Hodges' formulae for QT correction. The other age groups did not differ. No arrhythmia or atrioventricular conduction abnormalities were observed.Conclusion. Infants under 3 months of age on cisapride treatment had significantly longer QTc intervals (with Bazett's formula, the 98th percentile was 504 ms in the cisapride group vs 447 ms in controls). The clinical significance and risk of the increased QTc interval in these infants are unclear and need further evaluation and risk stratification. Meanwhile, cisapride should be judiciously prescribed in infants <3 months of age. Pediatrics 2000;106(6). URL: http://www.pediatrics.org/ cgi/content/full/106/6/e85; QT interval, QTc, cisapride, heart rate, heart rhythm, infants.ABBREVIATIONS. ECG, electrocardiogram; CYP, cytochrome P-450. C isapride, a prokinetic agent used in adults and children with gastrointestinal motility disorders, has been reported in some patients to increase the QT interval on the electrocardiogram (ECG). 1-3 Prolongation of the electrocardiographic QT interval may be either congenital 4 -6 or acquired. 7 Acquired prolongation of the QT interval can be caused by electrolyte disturbances (commonly hypokalemia and hypocalcemia), hypothermia, central nervous system injury, malnutrition, organophosphate poisoning, and medication. Medications that have been implicated include tricyclic antidepressants, macrolide antibiotics, phenothiazines, and antiarrhythmic agents. 7 The QT interval on the ECG represents the period from the beginning of depolarization (QRS complex) to the end of repolarization (T wave) of the ventricles. There are at least 5 different genes responsible for ...
The interval from the peak to the end of the T wave and the ratio of this value to the onset Q to T peak interval, represents regional dispersion of repolarization across the ventricular wall. This is a potentially useful clinical index in the assessment of arrhythmic risk in premature infants being treated by blockade of the I(Kr) channels.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.