As part of a continuing effort to improve U.S. Army combat clothing and equipment, four proposed Intermediate Cold-Wet Boots and the standard-issue U.S. Army Cold-Wet Vapor Barrier Boot were evaluated during a controlled chamber study to determine human physiological responses while sedentary and while performing intermittent exercise in simulated cold-wet conditions. The results showed that a dry, rubber, vapor-barrier boot provided increased foot protection while subjects were sedentary in a moderately cold environment. New leather footwear incorporating vapor-permeable, waterproof membranes were incapable of maintaining a dry interior after the boot had been subjected to a prolonged soak in shallow water. This moisture ingression increased boot weight and caused minor, albeit immobilizing injuries during intermittent exercise.
An evaluation was done on a prototype 70-mil permeable hood integrated to a standard 90-mil chemical protective overgarment to verify its potential in reducing heat strain during continuous exercise. Each of 14 subjects (in two groups of seven) did treadmill exercise (heat production, M = 473 W) in six environments: at ambient air temperature (Ta) = 32°C/80 %rh/ V=l m·s-1 and 5m·s-1; T2 = 35°C / 50 %rh / V=1 m·s-1 and 5 m·s-1; and Ta = 43°C / 20 %rh / V=1 m·s-1 and 5 m·s-1. Rectal (Tre), heart rate, 3-site skin temperatures, and head temperature and dewpoint in the skin-air space underneath each hood were recorded continuously. Subjects exercised until Tre reached 39°C and/or heart rates were = 180 beats/min for 5 min. These end-points signified the endurance time limit for each subject. The 70-mil semipermeable hood integrated to a BDO gave no significant advantages compared to the standard BDO + butyl hood in reduction of heat strain, improvement in vapor permeation to a given thermal insulation, and overall extension of endurance times. Present use of a butyl hood with an appropriate respiratory mask is a preferable option because of the reduced thickness of the hood which offers augmented heat transfer at high wind speeds.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.