Background: The wearable cardioverter-defibrillator (WCD) is available for patients at high risk for sudden cardiac death (SCD) when immediate implantable cardioverter-defibrillator (ICD) implantation is not possible or indicated. Patient selection remains challenging especially in primary prevention. Long-term data on these patients is still lacking. Methods: 153 patients were included in this study. They were prescribed the WCD between April 2012 and March 2019 at the University Medical Center, Mannheim, Germany. The mean follow-up period was 36.2 ± 15.6 months. Outcome data, including all-cause mortality, were analyzed by disease etiology and ICD implantation following WCD use. Results: We analyzed 56 patients with ischemic cardiomyopathy, 70 patients with non-ischemic cardiomyopathy, 16 patients with prior need for ICD/CRT-D (device for cardiac resynchronization therapy with defibrillator) explanation, 8 patients with acute myocarditis and 3 patients with congenital diseases. 58% of the patients did not need ICD/CRT-D implantation after WCD use. 4% of all patients suffered from appropriate WCD shocks. 2 of these patients (33%) experienced appropriate ICD shocks after implantation due to ventricular tachyarrhythmias. Long-term follow-up shows a good overall survival. All-cause mortality was 10%. There was no significant difference between patients with or without subsequent ICD implantation (p = 0.48). Patients with ischemic cardiomyopathy numerically showed a higher long-term mortality than patients with non-ischemic cardiomyopathy (14% vs. 6%, p = 0.13) and received significantly more ICD shocks after implantation (10% of ischemic cardiomyopathy (ICM) patients versus 3% of non-ischemic cardiomyopathy (NICM) patients, p = 0.04). All patients with ventricular tachyarrhythmias during WCD use or after ICD implantation survived the follow-up period. Conclusion: Following WCD use, ICD implantation could be avoided in 58% of patients. Long-term follow-up shows good overall survival. The majority of all patients did not suffer from WCD shocks nor did receive ICD shocks after subsequent implantation. Patient selection regarding predictive conditions on long-term risk of ventricular tachyarrhythmias needs further risk stratification.
Patients at high risk for sudden cardiac death (SCD) may benefit from wearable cardioverter defibrillators (WCD) by avoiding immediate implantable cardioverter defibrillator (ICD) implantation. Different factors play an important role including patient selection, compliance and optimal drug treatment. We aimed to present real world data from 4 centers from Germany and Switzerland. Between 04/2012 and 03/2019, 708 patients were included in this registry. Patients were followed up over a mean time of 28 ± 35.5 months. Outcome data including gender differences and different etiologies of cardiomyopathy were analyzed. Out of 708 patients (81.8% males, mean age 61.0 ± 14.6), 44.6% of patients had non-ischemic cardiomyopathy, 39.8% ischemic cardiomyopathy, 7.9% myocarditis, 5.4% prior need for ICD explantation and 2.1% channelopathy. The mean wear time of WCD was 21.2 ± 4.3 h per day. In 46% of patients, left ventricular ejection fraction (LVEF) was > 35% during follow-up. The younger the patient was, the higher the LVEF and the lower the wear hours per day were. The total shock rate during follow-up was 2.7%. Whereas an appropriate WCD shock was documented in 16 patients (2.2%), 3 patients received an inappropriate ICD shock (0.5%). During follow-up, implantation of a cardiac implantable electronic device was carried out in 34.5% of patients. When comparing German patients (n = 516) to Swiss patients (n = 192), Swiss patients presented with longer wear days (70.72 ± 49.47 days versus 58.06 ± 40.45 days; p = 0.001) and a higher ICD implantation rate compared to German patients (48.4% versus 29.3%; p = 0.001), although LVEF at follow-up was similar between both groups. Young age is a negative independent predictor for the compliance in this large registry. The most common indication for WCD was non-ischemic cardiomyopathy followed by ischemic cardiomyopathy. The compliance rate was generally high with a decrease of wear hours per day at younger age. Slight differences were found between Swiss and German patients, which might be related to differences in mentality for ICD implantation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.