Electrical impedance spectroscopy (EIS) is a potential, noninvasive technique to image women for breast cancer. Studies have shown characteristic frequency dispersions in the electrical conductivity and permittivity of malignant versus normal tissue. Using a multifrequency EIS system, we imaged the breasts of 26 women. All patients had mammograms ranked using the American College of Radiology (ACR) BIRADS system. Of the 51 individual breasts imaged, 38 were ACR 1 negative, six had ACR 4-5 suspicious lesions, and seven had ACR 2 benign findings such as fibroadenomas or calcifications. A radially translatable circular array of 16 Ag/AgCl electrodes was placed around the breast while the patient lay prone. We applied trigonometric voltage patterns at ten frequencies between 10 and 950 kHz. Anatomically coronal images were reconstructed from this data using nonlinear partial differential equation methods. Typically, ACR 1-rated breasts were interrogated in a single central plane whereas ACR 2-5-rated breasts were imaged in multiple planes covering the region of suspicion. In general, a characteristic homogeneous image emerged for mammographically normal cases while focal inhomogeneities were observed in images from women with malignancies. Using a specific visual criterion, EIS images identified 83% of the ACR 4-5 lesions while 67% were detected using a numerical criterion. Overall, multifrequency electrical impedance imaging appears promising for detecting breast malignancies, but improvements must be made before the method reaches its full potential.
There is increasing evidence that alterations in the electrical property spectrum of tissues below 10 MHz is diagnostic for tissue pathology and/or pathophysiology. Yet, the complexity associated with constructing a high-fidelity multichannel, multifrequency data acquisition instrument has limited widespread development of spectroscopic electrical impedance imaging concepts. To contribute to the relatively sparse experience with multichannel spectroscopy systems this paper reports on the design, realization and evaluation of a prototype 32-channel instrument. The salient features of the system include a continuously selectable driving frequency up to 1 MHz, either voltage or current source modes of operation and simultaneous measurement of both voltage and current on each channel in either of these driving configurations. Comparisons of performance with recently reported fixed-frequency systems is favorable. Volts dc (VDC) signal-to-noise ratios of 75-80 dB are achieved and the noise floor for ac signals is near 100 dB below the signal strength of interest at 10 kHz and 60 dB down at 1 MHz. The added benefit of being able to record multispectral information on source and sense signal amplitudes and phases has also been realized. Phase-sensitive detection schemes and multiperiod undersampling techniques have been deployed to ensure measurement fidelity over the full bandwidth of system operation.
We have deployed a recently completed spectroscopic electrical impedance tomography (EITS) imaging system in a small series of women (13 participants accrued to date) in order to investigate the feasibility of delivering EITS breast examinations on a routine basis. Hardware is driven with sinusoidally varying spatial patterns of applied voltage delivered to 16 electrodes over the 10 kHz to 1 MHz spectral range using a radially translating interface which couples the electrodes to the breast through direct contact. Imaging examinations have consisted of the acquisition of multi-channel measurements at ten frequencies on both breasts. Participants lie prone on an examination table with the breast to be imaged pendant in the electrode array that is located below the table. Examinations were comfortable and easy to deliver (about 10 minutes per breast including electrode-positioning time). Although localized near-surface electrode artefacts are evident in the acquired images, several findings have emerged. Permittivity images have generally been more informative than their conductivity counterparts, except in the case of fluid-filled cysts. Specifically, the mammographically normal breast appears to have characteristic absolute EITS permittivity and conductivity images that emerge across subjects. Structural features in the EITS images have correlated with limited clinical information available on participants with benign and malignant abnormality, cysts and scarring from previous lumpectomy and follow-up radiation therapy. Several cases from this preliminary experience are described.
Our previous system covered the frequency range of 0 to 1 MHz. In this new design we propose to cover the range from 0 to 10 MHz. The higher frequencies have forced us to reconsider several design decisions in view of both the physics of the problem and the performance of available electronic components. In this presentation we examine in detail the constraints faced by the designer, starting from wiring consideration to measurement techniques. We will also present the solutions we selected to overcome the limitations we discovered. The problems include phase detection, amplitude measurements, system organization and layout and finally system calibration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.