Summary
Background
For patients with end-stage renal disease who are not candidates for fistula, dialysis access grafts are the best option for chronic haemodialysis. However, polytetrafluoroethylene arteriovenous grafts are prone to thrombosis, infection, and intimal hyperplasia at the venous anastomosis. We developed and tested a bioengineered human acellular vessel as a potential solution to these limitations in dialysis access.
Methods
We did two single-arm phase 2 trials at six centres in the USA and Poland. We enrolled adults with end-stage renal disease. A novel bioengineered human acellular vessel was implanted into the arms of patients for haemodialysis access. Primary endpoints were safety (freedom from immune response or infection, aneurysm, or mechanical failure, and incidence of adverse events), and efficacy as assessed by primary, primary assisted, and secondary patencies at 6 months. All patients were followed up for at least 1 year, or had a censoring event. These trials are registered with ClinicalTrials.gov, NCT01744418 and NCT01840956.
Findings
Human acellular vessels were implanted into 60 patients. Mean follow-up was 16 months (SD 7·6). One vessel became infected during 82 patient-years of follow-up. The vessels had no dilatation and rarely had post-cannulation bleeding. At 6 months, 63% (95% CI 47–72) of patients had primary patency, 73% (57–81) had primary assisted patency, and 97% (85–98) had secondary patency, with most loss of primary patency because of thrombosis. At 12 months, 28% (17–40) had primary patency, 38% (26–51) had primary assisted patency, and 89% (74–93) had secondary patency.
Interpretation
Bioengineered human acellular vessels seem to provide safe and functional haemodialysis access, and warrant further study in randomised controlled trials.
Funding
Humacyte and US National Institutes of Health.
Objective:
The objective of this study was to evaluate the outcome of endovascular aortic arch repair for chronic dissection with a custom-made branched endograft.
Background:
Acute type A aortic dissections are often treated with prosthetic replacement of the ascending aorta. During follow-up, repair of an aneurysmal evolution of the false lumen distal to the ascending prosthesis can be a challenge both for the surgeon and the patient.
Methods:
We conducted a multicenter, retrospective study of consecutive patients from 14 vascular units treated with a custom-made, inner-branched device (Cook Medical, Bloomington, IN) for chronic aortic arch dissection. Rates of in-hospital mortality and stroke, technical success, early and late complications, reinterventions, and mortality during follow-up were evaluated.
Results:
Seventy consecutive patients were treated between 2011 and 2018. All patients were considered unfit for conventional surgery. In-hospital combined mortality and stroke rate was 4% (n = 3), including 1 minor stroke, 1 major stroke causing death, and 1 death following multiorgan failure. Technical success rate was 94.3%. Twelve (17.1%) patients required early reinterventions: 8 for vascular access complication, 2 for endoleak correction, and 2 for pericardial effusion drainage. Median follow-up was 301 (138–642) days. During follow-up, 20 (29%) patients underwent secondary interventions: 9 endoleak corrections, 1 open repair for prosthetic kink, and 10 distal extensions of the graft to the thoracic or thoracoabdominal aorta. Eight patients (11%) died during follow-up because of nonaortic-related cause in 7 cases.
Conclusions:
Endovascular treatment of aortic arch chronic dissections with a branched endograft is associated with low mortality and stroke rates but has a high reintervention rate. Further follow-up is required to confirm the benefits of this novel approach.
Although the risk of aneurysm rupture after EVAR is low, all patients treated endovascularly should be routinely monitored, in order to select cases with potential endoleaks or stentgraft migration which may lead to fatal complications. When rupture occurs open aneurysmectomy is feasible, although it requires careful management in these high-risk patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.