AimTo prospectively assess the antiinflammatory effect of volatile anesthetic sevoflurane in patients undergoing open lung surgery with one lung ventilation (OLV).MethodsThis prospective, randomized study included 40 patients undergoing thoracic surgery with OLV (NCT02188407). The patients were randomly allocated into two equal groups that received either propofol or sevoflurane. Four patients were excluded from the study because after surgery they received blood transfusion or non-steroid antiinflammatory drugs. Inflammatory mediators (interleukins 6, 8, and 10, C-reactive protein [CRP], and procalcitonin) were measured perioperatively. The infiltration of the nonoperated lung was assessed on chest x-rays and the oxygenation index was calculated. The major postoperative complications were counted.ResultsInterleukin 6 levels were significantly higher in propofol than in sevoflurane group (P = 0.014). Preoperative CRP levels did not differ between the groups (P = 0.351) and in all patients they were lower than 20 mg/L, but postoperative CRP was significantly higher in propofol group (31 ± 6 vs 15 ± 7 ng/L; P = 0.035); Pre- and postoperative procalcitonin was within the reference range (<0.04 µg/L) in both groups. The oxygenation index was significantly lower in propofol group (339 ± 139 vs 465 ± 140; P = 0.021). There was no significant difference between the groups in lung infiltrates (P = 0.5849). The number of postoperative adverse events was higher in propofol group, but the difference was not-significant (5 vs 1; P = 0.115).ConclusionThe study suggests an antiinflammatory effect of sevoflurane in patients undergoing thoracotomy with OLV.
Extracorporeal hemadsorption may reduce inflammatory reaction in cardiopulmonary bypass (CPB) surgery. Glucocorticoids have been used during open-heart surgery for alleviation of systemic inflammation after CPB. We compared intraoperative hemadsorption and methylprednisolone, with usual care, during complex cardiac surgery on CPB, for inflammatory responses, hemodynamics, and perioperative course. Seventy-six patients with prolonged CPB were recruited and randomized, with 60 included in final analysis. Allocation was into three groups: Methylprednisolone (n = 20), Cytosorb (n = 20), and Control group (usual care, n = 20). Proinflammatory (TNF-α, IL-1β, IL-6, and IL-8) and anti-inflammatory (IL-10) cytokines which complement C5a, CD64, and CD163 expression by immune cells were analyzed within the first five postoperative days, in addition to hemodynamic and clinical outcome parameters. Methylprednisolone group, compared to Cytosorb and Control had significantly lower levels of TNF-α (until the end of surgery, p<0.001), IL-6 (until 48 h after surgery, p<0.001), and IL-8 (until 24 h after surgery, p<0.016). CD64 expression on monocytes was the highest in the Cytosorb group and lasted until the 5th postoperative day (p<0.016). IL-10 concentration (until the end of surgery) and CD163 expression on monocytes (until 48 h after surgery) were the highest in the Methylprednisolone group (p<0.016, for all measurements between three groups). No differences between groups in the cardiac index or clinical outcome parameters were found. Methylprednisolone more effectively ameliorates inflammatory responses after CPB surgery compared to hemadsorption and usual care. Hemadsorption compared with usual care causes higher prolonged expression of CD64 on monocytes but short lasting expression of CD163 on granulocytes. Hemadsorption with CytoSorb® was safe and well tolerated. This trial is registered with clinicaltrials.gov (NCT02666703).
Objectives: Minimally invasive aortic valve replacement (mini-AVR) might improve clinical outcomes, particularly in high-risk and elderly patients. Sutureless/rapid deployment bioprosthesis can offer advantage of decreasing the cross-clamp time (XCT) and easing the procedure. Our aim was to evaluate the safety and perioperative outcomes of mini-AVR using sutureless bioprothesis via the right minithoracotomy approach with our modified technique of central cannulation. Methods: We performed a single-center retrospective analysis of 203 patients consecutively undergoing isolated AVR between March 2016 and June 2018 with the right minithoracotomy approach and our modified technique of central cannulation. Aortic valve diseases were stenosis (89.9%), regurgitation (1.6%), and mixed valve disease (8.5%). Patients with concomitant procedures were excluded. Primary endpoints were 30-day and 4-month mortality. Results: Mean age was 76 ± 6.2 years, 63 (31%) patients were 80 years or older. Cardiopulmonary bypass and XCT were 60.5 (39-153) and 35 (24-76) min, respectively. Thirty-day and 4-month mortality were 1% (two patients). We have observed minor paravalvular leak (PVL) which occurred in seven patients (3.4%), and no moderate/severe PVL was found perioperatively. One patient developed moderate/severe PVL during the 4-month follow-up. There was no structural valve degeneration. Two (1%) patients needed conversion to full sternotomy, and two (1%) patients to ministernotomy. Conclusions: Mini-AVR via the right minithoracotomy approach with central cannulation is an effective and safe procedure and demonstrates excellent early clinical outcomes. This approach can be particularly valuable in higher risk and elderly patients.
AimTo compare the outcomes of patients who underwent upper mini-sternotomy or right mini-thoracotomy and those who underwent full sternotomy and to report a technical improvement in venous drainage by means of double venous cannulation of the superior vena cava (SVC) in mini surgical procedures.MethodsWe retrospectively analyzed the outcome of 217 patients who underwent aortic valve replacement through upper mini-sternotomy or right mini-thoracotomy at the Department of Cardiovascular Surgery, University Medical Centre Ljubljana, Slovenia from 1996 till 2010. Cannulation of SVC and right atrial appendage was performed in 142/217 (65%) patients, while in the remaining 75 (35%) patients, double cannulation of SVC was used for venous drainage. The results of patients who underwent mini approaches were compared to 236 patients who underwent full sternotomy for the same purpose from 2009 to 2010 at the same center.ResultsWe found a shorter mean length of intensive care unit stay, less volume chest-tube drainage, shorter crossclamp and cardio pulmonary bypass times, and less postoperative permanent pacemaker implantations in the minimally invasive group patients than in full sternotomy group patients. Using double cannulation of the SVC for venous drainage made venous cannulation in mini approaches easier and eliminated the need for obtaining femoral venous access.ConclusionOur study confirmed that even though technically challenging, upper mini-sternotomy and right mini-thoracotomy approaches for aortic valve replacement have potential advantages over conventional median sternotomy. They were proved to be safe, efficacious, and can significantly reduce surgical trauma and are therefore particularly valuable in some higher risk, obese, diabetic and elderly patients. Using double cannulation of SVC for venous drainage made venous cannulation easier and eliminated the need for obtaining femoral venous access.
Objectives As aortic valve repair (AVr) for aortic insufficiency (AI) expands, minimally invasive (Mi) approaches are increasingly being applied. Cardiac surgical techniques can be more difficult through small incisions, and this report analyzes medium‐term outcomes for MiAVr facilitated by geometric ring annuloplasty. Methods Since 2013, 58 patients were selected for AVr through upper sternotomy third‐interspace incisions. The average age was 58.9 ± 15.4 (mean ± SD) years, 71% were male, and preoperative AI grade was 3.6 ± 0.8. Sixty‐two percent (36/58) had a proximal aortic replacement for ascending aortic aneurysms (n = 26) and/or remodeling grafts for aortic root aneurysms (n = 10). Annuloplasty rings were placed subannularly (69% trileaflet; 31% bicuspid), and leaflet procedures were performed in 70%. The average ring diameter was 21.6 ± 1.4 mm, and the average aortic clamp time was 113 ± 35 min. Results After repair, AI grade fell to an average of 0.5 ± 0.6 (p < .0001), with a mean valve gradient of 12.5 ± 7.1 mmHg. No operative mortalities or major complications occurred. Three patients required reoperations for bleeding, and two had pacemakers. At an average follow‐up of 38 months (maximal 88 months), three late deaths and no valve‐related complications were observed. Four patients required reoperative aortic valve replacement over follow‐up, and Kaplan–Meier survival and freedom from reoperation both exceeded 80% at 88 months. At the last follow‐up, the average AI grade was 0.7 ± 0.7, and the mean valve gradient was 12.7 ± 6.3 mmHg. Conclusions Geometric ring annuloplasty was safe and seemed to facilitate performing AVr ± proximal aortic replacement through Mi incisions. Hemodynamic improvements were significant, medium‐term clinical outcomes were acceptable, and results could improve further with experience.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.