The adoption of lean-burn technology in modern aero-engines influences the already critical aerothermal conditions at turbine entry, where the absence of dilution holes preserves the swirl component generated by burners and prevents any control on pattern factor. The associated uncertainty and lack of confidence entail the application of wide safety margins in turbine cooling design, with a detrimental effect on engine efficiency. Computational fluid dynamics (CFD) can provide a deeper understanding of the physical phenomena involved in combustor–turbine interaction, especially with hybrid Reynolds-averaged Navier–Stokes (RANS) large eddy simulation (LES) models, such as scale adaptive simulation (SAS), which are proving to overcome the well-known limitations of the RANS approach and be a viable approach to capture the complex flow physics. This paper describes the numerical investigation on a test rig representative of a lean-burn, effusion cooled, annular combustor developed in the EU Project Full Aerothermal Combustor-Turbine interactiOns Research (FACTOR) with the aim of studying combustor–turbine interaction. Results obtained with RANS and SAS were critically compared to experimental data and analyzed to better understand the flow physics, as well as to assess the improvements related to the use of hybrid RANS-LES models. Significant discrepancies are highlighted for RANS in predicting the recirculating region, which has slight influence on the velocity field at the combustor outlet, but affects dramatically mixing and the resulting temperature distribution. The accuracy of the results achieved suggests the exploitation of SAS model with a view to the future inclusion of the nozzle guide vanes in the test rig.
Modern lean burn aero-engine combustors make use of relevant swirl degrees for flame stabilization. Moreover, important temperature distortions are generated, in tangential and radial directions, due to discrete fuel injection and liner cooling flows respectively. At the same time, more efficient devices are employed for liner cooling and a less intense mixing with the mainstream occurs. As a result, aggressive swirl fields, high turbulence intensities, and strong hot streaks are achieved at the turbine inlet. In order to understand combustor-turbine flow field interactions, it is mandatory to collect reliable experimental data at representative flow conditions. While the separated effects of temperature, swirl, and turbulence on the first turbine stage have been widely investigated, reduced experimental data is available when it comes to consider all these factors together.In this perspective, an annular three-sector combustor simulator with fully cooled high pressure vanes has been designed and installed at the THT Lab of University of Florence. The test rig is equipped with three axial swirlers, effusion cooled liners, and six film cooled high pressure vanes passages, for a vortex-to-vane count ratio of 1:2. The relative clocking position between swirlers and vanes has been chosen in order to have the leading edge of the central NGV aligned with the central swirler. In order to generate representative conditions, a heated mainstream passes though the axial swirlers of the combustor simulator, while the effusion cooled liners are fed by air at ambient temperature. The resulting flow field exiting from the combustor simulator and approaching the cooled vane can be considered representative of a modern Lean Burn aero engine combustor with swirl angles above ±50 deg, turbulence intensities up to about 28% and maximum-to-minimum temperature ratio of about 1.25. With the final aim of investigating the hot streaks evolution through the cooled high pressure vane, the mean aerothermal field (temperature, pressure, and velocity fields) has been evaluated by means of a five-hole probe equipped with a thermocouple and traversed upstream and downstream of the NGV cascade.
Turbine inlet conditions in modern aero-engines employing lean-burn combustors are characterised by highly swirled flow and non-uniform temperature distributions. As a consequence of the lack of confidence in numerical predictions and the uncertainty of measurement campaigns, the use of wide safety margins is of common practice in the design of turbine cooling systems, thus affecting the engine performance and efficiency. Previous experiences showed how only scale-resolving approaches such as Large-eddy and Scale-adapting simulations are capable of overcoming the limitations of RANS, significantly improving the accuracy in the prediction of flow and temperature fields at the combustor outlet. However it is worth investigating the impact of such differences on the aerothermal performance of the NGVs, as to understand the limitations entailed in the current approach for their thermal design. Industrial applications in fact usually rely on 1D, circumferentially-averaged profiles of pressure, velocity and temperature at the combustor-turbine interface in conjunction with Reynolds-averaged Navier-Stokes (RANS) models. This paper describes the investigation performed on an experimental test case consisting of a combustor simulator equipped with NGVs. Three numerical modelling strategies were compared in terms of flow field and thermal loads on the film-cooled vanes: i) RANS model of the NGVs with inlet conditions obtained from a RANS simulation of the combustor; ii) RANS model of the NGVs with inlet conditions obtained from a Scale-Adaptive Simulation (SAS) of the combustor; iii) SAS model inclusive of both combustor and NGVs. The results of this study show that estimating the aerodynamics at the NGV exit does not demand particularly complex approaches, whereas the limitations of standard RANS models are highlighted again when the turbulent mixing is key. High-fidelity predictions of the conditions at the turbine entrance proved to be very beneficial to reduce discrepancies in the estimation of local adiabatic wall temperature of even 100 K. However, a further leap forward can be achieved with an integrated simulation, capable of reproducing the transport of the unsteady fluctuations generated in the combustor up into the turbine, which plays a key role in presence of film cooling. This work therefore points out how keeping the analysis of combustor and NGVs separate can lead to a significantly misleading estimation of the thermal loads and ultimately to a wrong thermal design of the cooling system.
In modern lean-burn aero-engine combustors, highly swirling flow structures are adopted to control the fuel-air mixing and to provide the correct flame stabilization mechanisms. Aggressive swirl fields and high turbulence intensities are hence expected in the combustor-turbine interface. Moreover, to maximize the engine cycle efficiency, an accurate design of the high-pressure nozzle cooling system must be pursued: in a film-cooled nozzle, the air taken from last compressor stages is ejected through discrete holes drilled on vane surfaces to provide a cold layer between hot gases and turbine components. In this context, the interactions between the swirling combustor outflow and the vane film cooling flows play a major role in the definition of a well-performing cooling scheme, demanding for experimental campaigns at representative flow conditions. An annular three-sector combustor simulator with fully cooled high-pressure vanes has been designed and installed at THT Lab of University of Florence. The test rig is equipped with three axial swirlers, effusion-cooled liners, and six film-cooled high-pressure vanes passages, for a vortex-to-vane count ratio of 1:2. The relative clocking position between swirlers and vanes has been chosen in order to have the leading edge of the central airfoil aligned with the central swirler. In this experimental work, adiabatic film effectiveness measurements have been carried out in the central sector vanes, in order to characterize the film-cooling performance under swirling inflow conditions. The pressure-sensitive paint (PSP) technique, based on heat and mass transfer analogy, has been exploited to catch highly detailed 2D distributions. Carbon dioxide has been used as coolant in order to reach a coolant-to-mainstream density ratio of 1.5. Turbulence and five-hole probe measurements at inlet/outlet of the cascade have been carried out as well, in order to highlight the characteristics of the flow field passing through the cascade and to provide precise boundary conditions. Results have shown a relevant effect of the swirling mainflow on the film cooling behavior. Differences have been found between the central airfoil and the adjacent ones, both in terms of leading edge stagnation point position and of pressure and suction side film coverage characteristics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.