Purpose. This study retrospectively analyzed the postoperative visual functions of myopic eyes implanted with multifocal intraocular lens (IOL) to evaluate the efficacy of multifocal IOL in highly myopic eyes. Methods. We studied 61 patients (96 eyes) who were implanted with multifocal IOL ZMA00 or ZMB00 (Abbott Medical Optics). The patients were stratified into two groups by axial length: 26 mm or above (AL ≥ 26 group) and below 26 mm (AL < 26 group). Postoperative corrected and uncorrected distance (5 m) and near (30 cm) visual acuity (VA), contrast sensitivity, and depth of focus were compared between two groups. Results. In the AL ≥ 26 group and the AL < 26 group, the mean ± standard deviation uncorrected distance logMAR VA at 12-month postoperative follow-up was −0.04 ± 0.11 and −0.01 ± 0.14, respectively; and the corrected distance VA was −0.17 ± 0.08 and −0.14 ± 0.07, with no significant differences between two groups (p = 0.558 and 0.101; Mann-Whitney U test). For near VA, the corresponding uncorrected VA was 0.06 ± 0.08 and 0.05 ± 0.09; and distance-corrected VA was 0.01 ± 0.06 and 0.01 ± 0.02, with no significant differences between two groups (p = 0.572, and 0.157; Mann-Whitney U test). Conclusion. The present study demonstrates that it is possible to achieve good uncorrected near and distance VA following implantation of multifocal IOL in eyes with long axial lengths.
ocular cyclotorsion when a patient changes from seated to supine position in cataract surgery and factors predicting the amount of cyclotorsion were investigated using VeRion system. Variables analyzed were age, gender, preoperative visual acuity, axial length, laterality of eyes, operative duration, and the direction and degree of cyclotorsion. The mean cyclotorsion of 107 eyes of 93 cataract patients was 0.98 ± 4.85 degrees (median, 1 degree; range, -11 to 12 degrees), and the median absolute value was 4 degrees (mean, 4.05 ± 2.82 degrees; range, 0 to 12 degrees). Cyclotorsion was ≥3 degrees in 68 (63.6%) eyes. Excyclotorsion occurred more frequently than incyclotorsion (50.5% vs. 43.0%). There was no cyclotorsion in seven (6.5%). Multiple regression analysis showed that gender was a significant predictive factor for the absolute value of cyclotorsion (β = 1.06, P = 0.041); however, the other variables had no effect on cyclotorsion. The absolute value of cyclotorsion was significantly larger in female than in male patients [median, 4 degrees and 3 degrees, respectively; mean, 4.66 ± 3.02 degrees and 3.44 ± 2.52 degrees, respectively (P = 0.039)]. In conclusion, cataract patients had significant posture-related ocular cyclotorsion. The amount of cyclotorsion was larger for female than male patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.