The two-phase heat transfer characteristics of degassed water flow boiling in horizontal mini-tubes are experimentally investigated in this paper. The inner diameters (di) of the tubes are 1.2mm, 1.6mm, and 2.0mm. Experiments are conducted with heat fluxes between 1.5kW/m2 and 155.75kW/m2 at mass fluxes of 21.19, 42.39, and 84.77kg/(m2s). The boiling curves of the three tubes are obtained. Incipient hysteresis is observed only in the tube with di = 1.2mm. Two-phase dominant heat transfer mechanisms are analyzed in the tubes with di = 1.2mm and di = 2.0mm based on the curves of local heat transfer coefficient versus vapor quality and the visualization results. The trend of peak value of the local heat transfer coefficient versus heat flux at different mass fluxes in the tube with di = 1.2mm is discussed in accordance with the thickness variation of the liquid film in annular flow.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.