BackgroundDue to the anatomical nature of the radial nerve, dissection and attainment of an adequate operative field in mid to distal humerus fracture is dangerous and limited. We devised a combined anterolateral and lateral approach that ensures protection of the radial nerve. This is achieved by performing bimodal dissection of the proximal humerus anteriorly and the distal humerus laterally.MethodsThirty-five consecutive patients were treated using a combined anterolateral and lateral approach for a minimum follow-up period of 24 months. We analyzed time to bony union, time to return to daily work, range of motion, elbow joint function as assessed by the Mayo elbow performance index and complications.ResultsRadiologic bony union was observed at 11.2 weeks (range, 8 to 20 weeks) on average. Four cases of incomplete radial nerve palsy before surgery all recovered. Time to return to work was 10.2 weeks (range, 2 to 32 weeks) on average. The average range of motion of the elbow was 3.3° (range, 0° to 10°) of extension and 135.9° (range, 125° to 145°) of flexion. There were 21 cases of excellent and 13 cases of good or better recovery, comprising over 97.1% on the Mayo elbow performance index. There were no complications of radial nerve palsy, non-union, mal-union, or infection.ConclusionsOur a modified combined anterolateral and lateral approach is a clinically effective surgical method of achieving protection of the radial nerve and securing easy and firm internal fixation.
PurposeThis study examined the rate of degeneration of acetabular cartilage by the bipolar head according to time, and also which clinical factors are related to the degeneration of acetabular cartilage.Materials and MethodsAmong 192 patients (226 hip joints) who received bipolar hemiarthroplasty from August 1996 to August 2002, 61 patients (65 hip joints) were enrolled in this study, who were followed up for more than 2 years and showed no signs of dislocation, infection, or functional problems. A modified form of a computer assisted vector wear analysis program was used to measure the rate of degeneration of the acetabular cartilage. The factors that appeared to affect the rate of acetabular degeneration in the two groups was evaluated.ResultsThe average linear degenerative change in the acetabular cartilage and the volumetric degenerative change were 0.23 ± 0.107 mm/year and 114 ± 47.2 mm3/year, respectively. The result showed significant differences in activity and HHS between the 2 groups. The HHS showed a reverse relationship with the linear degeneration and volumetric degeneration, and the activity showed a correlation with the linear and volumetric degeneration.ConclusionThe acetabular cartilage degenerates faster as the patient' activity increases, and slower with a higher HHS. When surgeons perform hip joint arthroplasty, it is strongly recommended that the life expectancy and the level of activity should be considered when deciding between a hemiarthroplasty and total hip arthroplasty.
Background: Unstable trochanteric femur fractures in elderly patients with osteoporosis are still challenging. Gamma3 nail with the U-blade lag screw (U-blade gamma nail) has been developed to improve mechanical stability of proximal femoral fragment. This study aimed to compare the clinical and radiologic outcomes of U-blade gamma nail to proximal femoral nail antirotation (PFNA), and standard Gamma3 nail (gamma nail) for unstable trochanteric femur fractures. Methods: A retrospective matched-pair case study was performed with U-blade gamma nail, PFNA, and gamma nail. During 2012-2018, 970 patients with unstable trochanteric femur fractures were reviewed. Matching criteria were set as follows: 1) sex; 2) age (± 3 years); 3) body mass index (± 2 kg/m2); 4) bone mineral density (± 1 T-score in femur neck). Finally, a total of 159 patients were enrolled. We assessed the tip-apex distance (TAD), neck shaft angle, and hip screw sliding distance using plain radiographs. Also, we evaluated the clinical outcomes with Koval’s grade and fixation failure during 2 years. Results: The mean postoperative TAD was not significantly different among the 3 groups (p = 0.519). However, the change in the TAD at 1 year (p = 0.027) and 2 years (p = 0.008) after surgery was significantly smaller in U-blade gamma nail group compared with PFNA and gamma nail group. The hip screw sliding distance at 1 year (p = 0.004) and 2 years (p = 0.001) after surgery was significantly smaller in U-blade gamma nail group compared with PFNA and gamma nail group. However, there was no significant difference of Koval’s grade and fixation failure among the 3 groups (p = 0.535). Conclusion: U-blade gamma nail showed favorable radiologic results in terms of the change in the hip screw position. However, U-blade gamma nail was not superior to PFNA and gamma nail in clinical outcomes.
Femoral neuropathy may be associated with various etiologies and can cause severe walking disability. We present the case of a 25-year-old woman who underwent surgical repair for a patella fracture and complained of lower extremity pain, paresthesia, and weakness postoperatively. Electromyography and magnetic resonance imaging (MRI) revealed partial peripheral neuropathy of the left femoral nerve associated with the patella fracture. To our knowledge, this is the first reported case of femoral neuropathy associated with a patella fracture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.