PVR is feasible during dobutamine stress. This index of global contractility is reasonably simple, does not affect the imaging time, and only minimally prolongs the off-line analysis time. It allows unmasking quite different, and heterogeneous, contractility reserve patterns underlying a given ejection fraction at rest. The best survival is observed in patients with up-sloping PVR, whereas flat-biphasic pattern is a strong predictor of cardiac events.
A cutaneous force-frequency relation recording system based on first heart sound amplitude vibrations has been recently validated. Second heart sound can be simultaneously recorded in order to quantify both systole and diastole duration.Aims: 1-To assess the feasibility and extra-value of operator-independent, force sensor-based, diastolic time recording during stress.
Methods:We enrolled 161 patients referred for stress echocardiography (exercise 115, dipyridamole 40, pacing 6 patients).The sensor was fastened in the precordial region by a standard ECG electrode. The acceleration signal was converted into digital and recorded together with ECG signal.Both systolic and diastolic times were acquired continuously during stress and were displayed by plotting times vs. heart rate. Diastolic filling rate was calculated as echo-measured mitral filling volume/sensor-monitored diastolic time.Results: Diastolic time decreased during stress more markedly than systolic time. At peak stress 62 of the 161 pts showed reversal of the systolic/diastolic ratio with the duration of systole longer than diastole. In the exercise group, at 100 bpm HR, systolic/diastolic time ratio was lower in the 17 controls (0.74 ± 0.12) than in patients (0.86 ± 0.10, p < 0.05 vs. controls).Diastolic filling rate increased from 101 ± 36 (rest) to 219 ± 92 ml/m 2 * s -1 at peak stress (p < 0.5 vs. rest).
Conclusion:Cardiological systolic and diastolic duration can be monitored during stress by using an acceleration force sensor. Simultaneous calculation of stroke volume allows monitoring diastolic filling rate.Stress-induced "systolic-diastolic mismatch" can be easily quantified and is associated to several cardiac diseases, possibly expanding the spectrum of information obtainable during stress.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.