The aim of this study was to evaluate and compare the electrical performance and properties of commercially available electroretinography (ERG) electrodes. Methods: A passive ionic model was used to measure impedance, noise, and potential drift in 10 types of ocular surface and skin ERG electrodes. Results: The impedance for silver-based ocular electrodes are generally lower (range, 65.35-343.3 Ω) with smaller phase angles (range, −6.41°to −33.91°) than gold-based electrodes (impedance ranged from 285.95 Ω to 2.913 kΩ, and phase angle ranged from −59.65°to −70.01°). Silver-based ocular electrodes have less noise (median line noise of 6.48 x 10 4 nV 2 /Hz) than gold-based electrodes (median line noise of 2.26 x 10 5 nV 2 /Hz). Although silver-based electrodes usually achieve a drift rate less than 5 μV/s within 15 minutes, gold-base ocular electrode cannot achieve a stable potential. The exception is the RETeval strip type of silver electrode, which had an unusual drift at 20 minutes. The noise spectral density showed no change over time indicating that noise was not dependent on the stabilization of the electrode. Conclusions: From the range of electrodes tested, lower impedance, lower capacitance, and lower noise was observed in silver-based electrodes. Stabilization of an electrode is effective against drift of the electrode potential difference but not the noise. Translational Relevance: Application of electrodes with optimized materials improve the quality of clinical electrophysiology signals and efficiency of the recording.
Purpose The purpose of the study was to determine if aqueous glucose levels rise in a comparable time frame to interstitial fluid and could therefore be suitable for a continuous glucose monitoring (CGM) site. Methods An intravenous glucose tolerance test was performed on five New Zealand white rabbits. Aqueous humor from the posterior and anterior chamber of the eye and venous blood were sampled for glucose concentration measurement. Glucose concentrations in the interstitial fluids were monitored using a CGM system. A compartment model was created to map the glucose response curves in each compartment. The delay in rising glucose concentrations between blood and interstitial fluid and aqueous humor in the posterior chamber and anterior chamber of the eye were analyzed. Results The results showed a statistically similar time lag and rate of change in glucose concentrations between blood and interstitial fluids or aqueous humor in either the posterior or anterior chamber. Conclusions The results of this study add further support to the aqueous humor being used as an alternative CGM site. Translational Relevance The study provides the basis for developing an intraocular continuous glucose sensor that can overcome limitations of current CGM systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.