Theoretical analysis
General transport equationThe partial differential equations which describe the conservation of mass species, momentum and heat in conjunction with turbulence models, can be expressed in a generalized form as
Major challenges are related to compressor and driver integration during run down. In order to understand these challenges, the pipeline compressor facility at Troll Kollsnes gas treatment plant, Norway, has been subjected to detailed trip testing and dynamic simulation analysis. The plant includes five pipeline compressors and is utilised as a pilot for analysing the transient response of a 40 MW compressor driven by a variable speed electric motor. The compressor control and protection system include an anti-surge and a hot gas bypass system. Vibration records have shown that under power outage the compressors were exposed to violent vibrations. Further investigation revealed that during a short power outage, the compressor enters the surge- and rotating stall area under certain operating scenarios. The rotating stall response resulted in reduced operating range and flexibility for the pipeline compressors. Specific precautions had to be taken to prevent the compressor from running into the low flow operating area of the performance envelope. Dynamic simulations cover important aspects related to the transient scenario analyses performed to reveal the root cause of the compressor problems. The simulation system enables sophisticated plant models to be configured from high quality standard model algorithm building blocks. Verification of the model blocks have been performed against plant records in order to validate the transient predictions. The paper reports experience from testing and verification of compressor and driver integration with reference to transient behaviour during run down. This includes the validation of the dynamic models, which apply both to the design and commissioning phase where actual plant trip tests should be used to verify the design and stability margins.
Knowledge of compressor system behaviour during trip is essential to obtain reliable operation. Experience at Troll Kollsnes gas treatment plant has shown that the compressor can suffer from surge and rotating stall in situations with voltage drops in the electricity grid. The electric motor driven compressor and the protection valves and piping has been modelled and dynamic simulations has been done to reveal the transient response. An elaborate plant model has been created with the dynamic simulation tool OTISS by AspenTech and tuned to represent the plant. The paper focuses on the impact of different compressor discharge volumes, dimensions of the recycle piping as well as the sizing, characteristics and trip signal delay of the recycle protection valve(s). Sensitivity analyses for the actual plant reveal the response and protection during compressor driver trip.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.