Children with diabetes improved glycemic control safely and effectively with short-term flash glucose monitoring compared to use of SMBG in a single arm study.
Background: A sensor-augmented insulin pump (SAP) using the MiniMed® 640G system with SmartGuard™ technology allows an automatic stop of insulin delivery based on prediction of low glucose levels. Since pediatric patients are particularly prone to hypoglycemia, this device may offer additional protection beyond conventional sensor-augmented therapy.Methods: This prospective, pediatric multicenter user evaluation assessed 6 weeks of SAP with SmartGuard (threshold setting for hypoglycemia: 70 mg/dL) compared to a preceding period of 2 weeks with SAP only. The primary outcome was the potential reduction in the frequency of hypoglycemic episodes and hypoglycemic intensity (area under the curve [AUC] and time <70 mg/dL).Results: The study included 24 patients with at least 3 months of insulin pump use (average age: 11.6 ± 5.1 years, 15 female, average type 1 diabetes duration: 7.5 ± 4.2 years, mean ± SD) who had on average 3.2 ± 1.0 predictive suspensions/patient/day. The mean sensor glucose minimum during suspension was 78 ± 6 mg/dL and the average suspension time was 155 ± 47 min/day. Use of SmartGuard in patients treated as per the protocol (n = 18) reduced the number of instances in which the glucose level was <70 mg/dL (1.02 ± 0.52 to 0.72 ± 0.36; P = 0.027), as well as AUC <70 mg/dL (0.76 ± 0.73 to 0.38 ± 0.24; P = 0.027) and the time/day the level fell below 70 mg/dL (73 ± 56 to 31 ± 22 min). The reduction of hypoglycemia was not associated with a significant change in mean glucose concentration (171 ± 26 to 180 ± 19 mg/dL, P = 0.111) and HbA1c (7.5% ± 0.5% to 7.6% ± 0.7%, (P = 0.329). Manual resumption of insulin delivery followed by carbohydrate intake resulted in significantly higher glucose levels 1 h after suspension compared to SmartGuard suspensions with automatic resume (190.8 ± 26.5 vs. 138.7 ± 10.3 mg/dL; P < 0.001).Conclusions: SmartGuard technology significantly reduced the risk for hypoglycemia in pediatric type 1 diabetes patients without increasing HbA1c. Patients must be educated that when using combining predictive low-glucose insulin suspension technology, extra carbohydrate intake in response to an alarm combined with manual resumption is likely to cause rebound hyperglycemia. The best results were achieved when the user did not interfere with pump operation.
Aims/hypothesis Hypoglycaemia during and after exercise remains a challenge. The present study evaluated the safety and efficacy of closed-loop insulin delivery during unannounced (to the closed-loop algorithm) afternoon physical activity and during the following night in young people with type 1 diabetes. Methods A randomised, two-arm, open-label, in-hospital, crossover clinical trial was performed at a single site in Slovenia. The order was randomly determined using an automated web-based programme with randomly permuted blocks of four. Allocation assignment was not masked. Children and adolescents with type 1 diabetes who were experienced insulin pump users were eligible for the trial. During four separate in-hospital visits, the participants performed two unannounced exercise protocols: moderate intensity (55% of V Á O 2max ) and moderate intensity with integrated highintensity sprints (55/80% of V Á O 2max ), using the same study device either for closed-loop or open-loop insulin delivery. We investigated glycaemic control during the exercise period and the following night. The closed-loop insulin delivery was applied from 15:00 h on the day of the exercise to 13:00 h on the following day.Results Between 20 January and 16 June 2016, 20 eligible participants (9 female, mean age 14.2 ± 2.0 years, HbA 1c 7.7 ± 0.6% [60.0 ± 6.6 mmol/mol]) were included in the trial and performed all trial-mandated activities. The median proportion of time spent in hypoglycaemia below 3.3 mmol/l was 0.00% for both treatment modalities (p = 0.7910). Use of the closed-loop insulin delivery system increased the proportion of time spent within the target glucose range of 3.9-10 mmol/l when compared with open-loop delivery: 84.1% (interquartile range 70.0-85.5) vs 68.7% (59.0-77.7), respectively (p = 0.0057), over the entire study period. This was achieved with significantly less insulin delivered via the closed-loop (p = 0.0123). Conclusions/interpretation Closed-loop insulin delivery was safe both during and after unannounced exercise protocols in the in-hospital environment, maintaining glucose values mostly within the target range without an increased risk of hypoglycaemia.Trial registration Clinicaltrials.gov NCT02657083 Funding
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.