Continuous-flow left ventricular assist devices (LVADs) have greatly improved the prognosis of patients with end-stage heart failure, even if continuous flow is different from physiological flow in that it has less pulsatility. A novel pump controller of continuous-flow LVADs has been developed, which can change its rotational speed (RS) in synchronization with the native cardiac cycle, and we speculated that pulsatile mode, which increases RS just in the systolic phase, can create more pulsatility than the current system with constant RS does. The purpose of the present study is to evaluate the effect of this pulsatile mode of continuous-flow LVADs on pulsatility in in vivo settings. Experiments were performed on eight adult goats (61.7 ± 7.5 kg). A centrifugal pump, EVAHEART (Sun Medical Technology Research Corporation, Nagano, Japan), was installed by the apex drainage and the descending aortic perfusion. A pacing lead for the detection of ventricular electrocardiogram was sutured on the anterior wall of the right ventricle. In the present study, we compared pulse pressure or other parameters in the following three conditions, including Circuit-Clamp (i.e., no pump support), Continuous mode (constant RS), and Pulsatile mode (increase RS in systole). Assist rate was calculated by dividing pump flow (PF) by the sum of PF and ascending aortic flow (AoF). In continuous and pulsatile modes, these assist rates were adjusted around 80-90%. The following three parameters were used to evaluate pulsatility, including pulse pressure, dp/dt of aortic pressure (AoP), and energy equivalent pulse pressure (EEP = (∫PF*AoP dt)/(∫PF dt), mm Hg). The percent difference between EEP and mean AoP is used as an indicator of pulsatility, and normally it is around 10% of mean AoP in physiological pulse. Both pulse pressure and mean dp/dt max were decreased in continuous mode compared with clamp condition, while those were regained by pulsatile mode nearly to clamp condition (pulse pressure, clamp/continuous/pulsatile, 25.0 ± 7.6/11.7 ± 6.4/22.6 ± 9.8 mm Hg, mean dp/dt max, 481.9 ± 207.6/75.6 ± 36.2/351.1 ± 137.8 mm Hg/s, respectively). In clamp condition, %EEP was 10% higher than mean AoP (P = 0.0078), while in continuous mode, %EEP was nearly equivalent to mean AoP (N.S.). In pulsatile mode, %EEP was 9% higher than mean AoP (P = 0.038). Our newly developed pulsatile mode of continuous-flow LVADs can produce pulsatility comparable to physiological pulsatile flow. Further investigation on the effect of this novel drive mode on organ perfusion is currently ongoing.
The effect of rotary left ventricular assist devices (LVADs) on myocardial perfusion has yet to be clearly elucidated, and several studies have shown decreased coronary flow under rotary LVAD support. We have developed a novel pump controller that can change its rotational speed (RS) in synchronization with the native cardiac cycle. The aim of our study was to evaluate the effect of counterpulse mode, which increases the RS in diastole, during coronary perfusion. Experiments were performed on ten adult goats. The EVAHEART LVAD was installed by the left ventricular uptake and the descending aortic return. Ascending aortic flow, pump flow, and coronary flow of the left main trunk were monitored. Coronary flow was compared under four conditions: circuit-clamp, continuous mode (constant pump speed), counterpulse mode (increased pump speed in diastole), and copulse mode (increased pump speed in systole). There were no significant baseline changes between these groups. In counterpulse mode, coronary flow increased significantly compared with that in continuous mode. The waveform analysis clearly revealed that counterpulse mode mainly resulted in increased diastolic coronary flow. In conclusion, counterpulse mode of rotary LVADs can enhance myocardial perfusion. This novel drive mode can provide great benefits to the patients with end-stage heart failure, especially those with ischemic etiology.
There are many reports comparing pulsatile and continuous-flow left ventricular assist devices (LVAD). But continuous-flow LVAD with the pulsatile driving technique had not been tried or discussed before our group's report. We have previously developed and introduced a power-control unit for a centrifugal LVAD (EVAHEART®; Sun Medical), which can change the speed of rotation so it is synchronized with the heart beat. By use of this unit we analyzed the end-diastolic volume (EDV) to determine whether it is possible to change the native heart load. We studied 5 goats with normal hearts and 5 goats with acute LV dysfunction because of micro-embolization of the coronary artery. We used 4 modes, "circuit-clamp", "continuous", "counter-pulse", and "co-pulse", with the bypass rate (BR) 100%. We raised the speed of rotation of the LVAD in the diastolic phase with the counter-pulse mode, and raised it in the systolic phase with the co-pulse mode. As a result, the EDV decreased in the counter-pulse mode and increased in the co-pulse mode, compared with the continuous mode (p < 0.05), in both the normal and acute-heart-failure models. This result means it may be possible to achieve favorable EDV and native heart load by controlling the rotation of continuous-flow LVAD, so it is synchronized with the cardiac beat. This novel driving system may be of great benefit to patients with end-stage heart failure, especially those with ischemic etiology.
We evaluated the advantages of three-dimensional (3D) culture in a collagen hydrogel for stem cell differentiation, including the morphology of differentiated cells, differentiation efficiency of stem cells from aged rat and cells after passaging and freeze/thawing. Rat mesenchymal stem cells (MSCs) from young and aged rats, and MSCs after passaging and freeze/thawing were induced to differentiate into osteoblasts in 3D and 2D cultures, and histological studies were performed. Differentiation efficiency was evaluated by markers of osteoblastic differentiation including Runx2 and osterix gene expressions, osteocalcin secretion and calcium deposition. MSCs were stained positive for alkaline phosphatase in 3D and 2D cultures. However, the morphology of differentiated cells in 3D culture, which was different from that in 2D culture, was similar to that of osteoblasts in vivo. Markers of osteoblastic differentiation in MSCs from aged rats in 3D culture were higher than those in MSCs from young rats in 2D culture. Markers of osteoblastic differentiation in MSCs after passaging and freeze/thawing in 3D culture were higher than those in nonpassaged MSCs in 2D culture. These results indicate that 3D culture in a collagen hydrogel has advantages for the differentiation of MSCs into osteoblasts with a similar phenotype to that of in vivo, when using even MSCs from aged donors or after passaging and freeze/thawing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.