The
development of highly efficient, selective, and durable photocatalytic
CO2 reduction systems that only use earth-abundant elements
is key for both solving global warming and tackling the shortage of
energy and carbon resources. Here, we successfully developed CO2 reduction photocatalysts using [Cu2(P2bph)2]2+ (CuPS) (P2bph = 4,7-diphenyl-2,9-di(diphenylphosphinotetramethylene)-1,10-phenanthroline)
as a redox photosensitizer and fac-Mn(X2bpy)(CO)3Br (Mn(4X)) (X2bpy =
4,4′-X2-2,2′-bipyridine (X = −H and
−OMe) or Mn(6mes) (6mes = 6,6′-(mesityl)2-2,2′-bipyridne)) as the catalyst. The most efficient
photocatalysis was achieved by Mn(4OMe): The total quantum
yield of CO2 reduction products was 57%, the turnover number
based on the Mn catalyst was over 1300, and the selectivity of CO2 reduction was 95%. Electronic and steric effects of the substituents
(X) in the Mn complexes largely affected both the photocatalytic efficiency
and the product selectivity. For example, the highest selectivity
of CO formation was achieved by using Mn(6mes) (selectivity S
CO = 96.6%), whereas the photocatalytic system
using Mn(4H) yielded HCOOH as the main product (S
HCOOH = 74.6%) with CO and H2 as
minor products (S
CO = 23.7%, S
H2
= 1.7%). In these photocatalytic reactions, CuPS played its role as an efficient and very durable redox
photosensitizer, while remaining stable in the reaction solution even
after a turnover number of 200 had been reached (the catalyst used
had a turnover number of over 1000).
RTx of adult‐size kidneys presents a size mismatch in small pediatric recipients, and there are potential surgical complications. This study reveals the outcomes of intra‐ and extraperitoneal RTx in low‐weight (less than 15 kg) pediatric recipients. We studied 51 pediatric patients weighing less than 15 kg who received a living‐related donor renal transplant between 2009 and 2017. The intraperitoneal (group A, n = 24) and extraperitoneal (group B, n = 27) approaches were compared. In group A, the mean age, Ht, and weight were 3.8 ± 1.6 years, 83.7 ± 6.5 cm, 10.5 ± 1.8 kg; in group B, 5.0 ± 1.9 years, 95.3 ± 7.3 cm, and 13.0 ± 1.4 kg. Single renal artery grafts (21 in group A and 16 in group B) and double renal artery grafts (three in group A and 11 in group B) were performed. Of the patients with double renal artery transplants, one in group A and six in group B underwent ex vivo arterial reconstruction. The eGFR (mL/min/1.73 m2) at 1‐week post‐transplant in group A was significantly higher than that in group B; the eGFRs at 4 weeks post‐transplant did not differ. One graft was lost in group B because of vascular thrombosis. Post‐transplant complications included ileus and transplant ureteral stenosis. There was no significant difference in 5‐year graft survival rate (group A 100%, group B 91.7%). Both transplant approaches are feasible to adapt to a size mismatch between the adult‐size donor kidney and low‐weight pediatric recipients.
Aneurysm of autogenous arteriovenous fistula is a common complication in patients receiving hemodialysis. We present a novel method for repair of a case of aneurysm of arteriovenous fistula resulting from stenosis. A 52-year-old woman presented with aneurysm formation of the left upper arm arteriovenous fistula, with related numbness in the left hand. Clinical examination revealed a tense, pulsatile aneurysm above the brachiocephalic anastomosis. Ultrasound examination revealed an aneurysm (50 mm × 25 mm) with proximal stenosis and an arteriovenous fistula flow rate above 1200 mL/ min. An incision was made lateral to the aneurysm from the brachiocephalic anastomosis to the proximal stenosis through the antecubital fossa. After exposure of the entire aneurysmal arteriovenous fistula, the narrowed segment, and the proximal cephalic vein, the aneurysm outflow was ligated and the narrowed segment was removed. A U-shaped incision was made on the aneurysm to create an aneurysmal flap (75 mm × 20 mm). The flap was tubularized after calibration of the lumen with a 14-Fr cannula. End-to-end anastomosis was performed between the distal tubularized flap and the proximal cephalic vein. Intra-and postoperative arteriovenous fistula flow rates were below 900 mL/min. After surgery, the remodeled arteriovenous fistula was immediately usable for hemodialysis with normal arteriovenous fistula flow in the upper arm. The repair technique achieved not only aneurysmorrhaphy but also created an autologous vascular graft as the bypass after removal of the narrowed segment. Moreover, this technique achieved reduced arterial inflow and is suitable for patients with conditions similar to those of this case.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.