Immunoadsorption with a tryptophan-conjugated column has a limited capacity and reduces fibrinogen. We speculated that immunoadsorption with a selective plasma separator has higher efficiency in removing immunoglobulins than ordinary immunoadsorption without affecting coagulation factors. This study investigated the efficacy of immunoadsorption with a selective plasma separator in vitro. The sieving coefficients, the pool concentration, and the adsorbed amount were investigated serially with up to 5 L of processed plasma. The sieving coefficients of the selective plasma separator were 0.8, 0.5, and 0.1 for albumin, immunoglobulin G (IgG), and factor 13, respectively. The trend of concentrations for the ordinary plasma separator in the pool reached its nadir at 1.5 L and 3.5 L of plasma processed for IgG, IgG1, or IgG2, and IgG3, respectively. However, the volume was doubled for the selective plasma separator. The trends of fibrinogen and factor 13 concentrations differed significantly between two plasma separators. The trends of the absorbed amount were mirror images of the concentration in the pool. Comparison of the peak amount absorbed indicated that the amounts were almost identical between the two separators for IgG, IgG1, and IgG2. On the other hand, the peak amounts were less for albumin, fibrinogen, and IgG3 with the selective plasma separator than with the ordinary separator. Although further investigations about bradykinin are required, immunoadsorption with the selective plasma separator supports the administration of more frequent and intensive treatments to remove IgG1 or IgG2 without affecting coagulation factors.
Background: Needle insertion pain associated with maintenance hemodialysis (HD) causes considerable stress on HD patients with native arteriovenous fistula. Skin cooling has been suggested to modify pain sensitivity and reduce needle insertion pain. Recently, a skin cooling device, named Mutsu-Senshi®, has been developed to decrease local skin temperature to 21°C smoothly and safely at the bedside. Therefore, we examined the effectiveness of Mutsu-Senshi® in 4 HD centers in Japan.
Non-anticoagulant hemodialysis is conducted occasionally at limited numbers of hospitals on an empirical basis. This study examines the efficacy of polysulfone and vitamin E-bonded polysulfone dialyzer for non-anticoagulant hemodialysis. These dialyzers were assigned one after the other for a vintage hemodialysis patient complicated with uncontrollable bleeding. The patient's vital and console data throughout non-anticoagulant hemodialysis were monitored serially. Both dialyzers were reasonably applicable to hemodialysis without major clotting. The scheduled treatment period was completed. Vitamin E-bonded polysulfone dialyzer was superior to non-anticoagulant hemodialysis based on venous pressure observed during treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.