In the catheter ablation for AF, we found no significant reduction in the 1-year incidence of recurrent atrial tachyarrhythmias by ATP-guided PVI compared with conventional PVI.
Short-term use of AAD for 90 days following AF ablation reduced the incidence of recurrent atrial tachyarrhythmias during the treatment period, but it did not lead to improved clinical outcomes at the later phase.
Background-We investigated the possibility that a frequent trigger action might play a role in the development of persistent atrial fibrillation (PeAF) and the presence of a substrate. Methods and Results-In 263 consecutive patients who underwent catheter ablation (CA) for PeAF, electric cardioversion was performed at the beginning of the procedure to determine the presence or absence of an immediate recurrence of AF (IRAF).We defined an IRAF as a reproducible AF recurrence within 90 s after restoration of sinus rhythm by electric cardioversion.We performed a meanϮSD of 1.3Ϯ0.5 sessions of CA, including pulmonary vein isolation and ablation of the premature atrial contractions that triggered the IRAF (IRAF triggers), and observed the patients for 17 (10 -27) months. An IRAF was observed in 70 patients (27%), but we could not ablate the IRAF triggers in 16 (23%) of these IRAF patients. The recurrence rate of PeAF was higher in patients with an unsuccessful IRAF trigger ablation than in those with successful IRAF trigger ablation (63% versus 11%; PϽ0.001). A multivariable analysis also revealed that an unsuccessful IRAF trigger ablation was 1 of the independent predictors of recurrent PeAF (odds ratio, 10.9; 95% CI, 3.4 -36.7). Conclusions-In the PeAF patients with an IRAF, successful elimination of the IRAF triggers, in addition to pulmonary vein isolation, resulted in a successful CA. These results imply that such triggers play a major role in the AF persistence in these PeAF patients. (Circ Arrhythm Electrophysiol. 2012;5:295-301.)
Chronic pre-treatment with statins could preserve the microvascular integrity after acute myocardial infarction independent of lipid lowering, leading to better functional recovery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.