We developed and validated an EA risk scale for children receiving sevoflurane anesthesia. In our validation cohort, this scale has excellent predictive performance (c-index > 0.8). The EA risk scale could be used to predict EA in children and adopt a preventive strategy for those at high risk. This score-based preventive approach should be studied prospectively to assess the safety and efficacy of such a strategy.
BackgroundEmergence agitation (EA) is a frequent phenomenon in children recovering from general anaesthesia and increases the risk of self-injury. Previously, our group reported that stimulating the heart 7 (HT7) acupuncture point bilaterally using two neuromuscular transmission monitoring devices (NTMs) decreased the incidence of EA. However, bilateral stimulation is a barrier to clinical use because two NTMs are needed for one patient.ObjectiveThe objective of this study was to examine the efficacy of unilateral electrical stimulation of HT7 using an NTM to prevent EA in children.DesignProspective, double-blinded, randomized clinical trial.SettingKanagawa Children’s Medical Centre, Yokohama, Japan.PatientsOne hundred children (ages 18–96 months) with ASA-PS I or II, who were scheduled to undergo inguinal hernia repair or orchiopexy under sevoflurane anaesthesia.InterventionPatients were randomly assigned to one of the following two groups: (1) HT7 group: unilateral (right side) stimulation of the HT7 acupuncture point using a single-twitch electrical stimulus (1 Hz, 50 mA) throughout the surgery, and (2) control group: electrodes alone were attached to the HT7 point on the right side; an electrical stimulus was not applied.Main outcome measuresThe primary outcome was the incidence of EA evaluated using the pediatric anaesthesia emergence delirium (PAED) scale. The secondary outcomes were the incidence of EA evaluated using Aono’s scale, the severity of EA, PACU stay duration, and postoperative pain.ResultsThere was no statistical difference between the incidence of EA in the HT7 and the control group (28.0% and 24.0%, respectively; P > 0.99). The risk ratio was 1.17 (95% confidence interval: 0.60–2.27).ConclusionsWe observed that there was no effect of unilateral single-twitch electrical stimulation to the HT7 on the incidence of EA, contrary to the findings with bilateral HT7 stimulation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.