We compared a fluorescein-conjugated monoclonal antibody (FA) direct specimen test (MicroTrak; Syva Co., Palo Alto, Calif.) with culture (TC) in McCoy cells (vials, with blind passage and iodine staining of inclusions) for diagnosis of Chlamydia trachomatis infection in the cervix. Duplicate specimens were collected from 1,230 women, but for 262 of these subjects, both results were unavailable (150 FA smears were inadequate, indicating a need for clinician training in specimen collection), leaving 968 comparisons. Prevalence of chlamydiae by culture was 13% (126/968). Compared with TC results, the sensitivity of FA was 70% (88/126) and the specificity was 94% (795/842). there was a 91% agreement (883/968). The predictive value of a positive FA test was 65% (88/135), and that of a negative FA was 95% (795/833). We reexamined 38 smears for which paired results were discrepant, and the reread would have changed the result in only 5 of these. TC is <100% sensitive and some FA-positive, TC-negative specimens represent positive specimens not detected by TC. Unfortunately, it is not possible to identify which results in this group are truly false-positive. Clearly, the FA procedure has a performance profile which would make it a useful tool in screening high-risk populations (pafrticularly when TC is not available) but it is less suited to screening low-risk populations, for which false-positive results are more important. The greater utility of the FA procedure in a venereal disease clinic was confirmed by testing 172 evaluable specimen pairs, of which 34 (20%) were Chlamydia isolate positive. The FA sensitivity was 76% (26/34) and specificity was 96% (133/138), giving a predictive value of 84% (26/31) for a positive test. * Corresponding author. antibody (FA) system with TC in diagnosing cervical chlamydial infection in three populations of women.
A new microparticle enzyme immunoassay (MEIA), the Cytomegalovirus (CMV) Immunoglobulin M (IgM) test, was developed on the Abbott AxSYM analyzer. This test uses recombinant CMV antigens derived from portions of four structural and nonstructural proteins of CMV: pUL32 (pp150), pUL44 (pp52), pUL83 (pp65), and pUL80a (pp38). A total of 1,608 specimens from random volunteer blood donors (n = 300), pregnant women (n = 1,118), transplant recipients (n = 6), and patients with various clinical conditions and disease states (n = 184) were tested during development and evaluation of this new assay. In a preliminary clinical evaluation we tested specimens collected prospectively from pregnant women (n = 799) and selected CMV IgM-positive archived specimens from pregnant women (n = 39). The results from the new CMV IgM immunoassay were compared to the results of a consensus interpretation of the results obtained with three commercial CMV IgM immunoassays. The results for specimens with discordant results were resolved by a CMV IgM immunoblot assay. The relative sensitivity, specificity, and agreement for the AxSYM CMV IgM assay were 94.29, 96.28, and 96.19%, respectively, and the resolved sensitivity, specificity, and agreement were 95.83, 97.47, and 97.37%, respectively. We also tested serial specimens from women who experienced seroconversion or a recent CMV infection during gestation (n = 17) and potentially cross-reactive specimens negative for CMV IgM antibody by the consensus tests (n = 184). The AxSYM CMV IgM assay was very sensitive for the detection of CMV IgM during primary CMV infection, as shown by the detection of CMV IgM at the same time as or just prior to the detection of CMV IgG. Specimens from individuals with lupus (n = 16) or parvovirus B19 infection (n = 6) or specimens containing hyper IgM (n = 9), hyper IgG (n = 8), or rheumatoid factor (n = 55) did not cross-react with the AxSYM assay. One specimen each from individuals infected with Epstein-Barr virus (n = 26), measles virus (n = 10), herpes simplex virus (n = 12), or varicella-zoster virus (n = 13) infection, one specimen from an influenza vaccinee (n = 14), and one specimen containing antinuclear antibody cross-reacted with the assay. The overall rate of cross-reactivity of the specimens with the assay was 3.3% (6 of 184). The AxSYM CMV IgM assay is a sensitive and specific assay for the detection of CMV-specific IgM.
Although this assay is a sensitive test for CMV-specific IgM, detection of CMV IgM preceded detection of virus by culture in patients only when the liver transplant recipient was CMV immune before transplantation (R+).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.