We developed a selective and sensitive hyphenated system employing a microfluidic-based vapor generation (VG) system in conjunction with high-performance liquid chromatography (HPLC) separation and inductively coupled plasma-mass spectrometry (ICPMS) detection for the determination of trace inorganic selenium (Se) species. The VG system exploited poly(methyl methacrylate) (PMMA) substrates of high optical quality to fabricate a microfluidic-based photocatalyst-assisted reduction device (microfluidic-based PCARD). Moreover, to reduce the consumption of photocatalysts during analytical procedures, a microfluidic-based PCARD coated with titanium dioxide nanoparticles (nano-TiO2) was employed to avoid consecutive loading. Notably, to simplify the coating procedure and improve the stability of the coating materials, a dynamic coating method was utilized. Under the optimized conditions for the selenicals of interest, the online HPLC/TiO2-coated microfluidic-based PCARD/ICPMS system enabled us to achieve detection limits (based on 3σ) of 0.043 and 0.042 μg L(-1) for Se(IV) and Se(VI), respectively. Both Se(IV) and Se(VI) could be efficiently vaporized within 15 s, while a series of validation experiments indicated that our proposed method could be satisfactorily applied to the determination of inorganic Se species in the environmental water samples.
Traditional Chinese herbal medicine has long enjoyed the reputation of the world's most advanced system of natural medicine. Pinellia ternata is one of the most commonly used herbs in the traditional Chinese medical science. In this study, five representative ingredients of Pinellia ternata guanosine, methionine, glycine, 3,4-dihydroxybenzaldehyde, and homogentisic acid, were assayed using simple derivatization procedures. Under optimized experimental condition, five analytes in Pinellia ternata were rapidly separated and detected using microchip electrophoresis, affording the benefits of speed, minimal sample requirements, and sensitive on-the-chip electrochemical detection, in 5 min with linearity over a concentration of 20-500 μM (R = 0.994) with nearly complete recovery (95.6-98.5%).
To selectively and sensitively determine the trace inorganic As species, As(III) and As(V), we developed a nanocomposite-coated microfluidic-based photocatalyst-assisted reduction device (PCARD) as a vapor generation (VG) device to couple high-performance liquid chromatography (HPLC) separation and inductively coupled plasma-mass spectrometry (ICPMS) detection. Au nanoparticles were deposited on TiO nanoparticles to strengthen the conversion efficiency of the nanocomposite photocatalytic reduction. The sensitivity for As was significantly enhanced by employing the nanocomposite photocatalyst and using prereduction and signal-enhancement reagents. Under the optimal operating conditions, the analytical detection limits (based on 3σ) of the proposed online HPLC/nanocomposite-coated microfluidic-based PCARD/ICPMS system for As(III) and As(V) were 0.23 and 0.34 μg·L, respectively. The results were validated using a certified reference material (NIST SRM 1643e) and groundwater sample analysis, indicating the good reliability and applicability of our proposed system for the determination of inorganic As species in natural fresh water.
We employed a polymeric material, poly(methyl methacrylate) (PMMA), for fabricating a microdevice and then implanted the chlorine (Cl)-containing solid-phase extraction (SPE) functionality into the PMMA chip to develop an innovative on-chip dipole-assisted SPE technique. Instead of the ion-ion interactions utilized in on-chip SPE techniques, the dipole-ion interactions between the highly electronegative C-Cl moieties in the channel interior and the positively charged metal ions were employed to facilitate the on-chip SPE procedures. Furthermore, to avoid labor-intensive manual manipulation, a programmable valve manifold was designed as an interface combining the dipole-assisted SPE microchip and inductively coupled plasma-mass spectrometry (ICP-MS) to achieve the fully automated operation. Under the optimized operation conditions for the established system, the detection limits for each analyte ion were obtained based on three times the standard deviation of seven measurements of the blank eluent solution. The limits ranged from 3.48 to 20.68 ng L(-1), suggesting that this technique appears uniquely suited for determining the levels of heavy metal ions in natural water. Indeed, a series of validation procedures demonstrated that the developed method could be satisfactorily applied to the determination of trace heavy metals in natural water. Remarkably, the developed device was durable enough to be reused more than 160 times without any loss in its analytical performance. To the best of our knowledge, this is the first study reporting on the combination of a dipole-assisted SPE microchip and elemental analysis instrument for the online determination of trace heavy metal ions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.