Because bowel gas deteriorates the image quality of abdominal ultrasonography (AUS), it is common to perform AUS prior to esophagogastroduodenoscopy (EGD). This one-way order limits the availability of examination appointments. To evaluate whether EGD using insufflation of carbon dioxide (CO2), which is rapidly absorbed by the gastrointestinal mucosa, preserves the image quality of AUS performed subsequently, we designed a non-inferiority test in which each subject underwent AUS, EGD with CO2 insufflation, and a second AUS. All saved AUS moving images were randomized and evaluated using a four-point Likert scale that divides the depiction rate by 25%. Sample size was calculated to be 26 and 30 subjects were enrolled. The mean and 95% confidence interval (CI) of the image quality score at pre- and post-EGD AUS were 3.54 [3.48–3.60] and 3.46 [3.39–3.52], respectively. The difference in the means was 0.08, corresponding to a 2% depiction rate. The effect size was 0.172. The image quality of post-EGD AUS was not inferior, as demonstrated by the 97.5% CI of the difference, which did not cross the non-inferiority margin of –0.40 corresponding to depiction rate of –10%. Because EGD using CO2 insufflation does not appreciably deteriorate the image quality of AUS performed subsequently, it is permissible to perform EGD prior to AUS.
Because bowel gas deteriorates the image quality of abdominal ultrasonography (AUS), it is common to perform AUS prior to esophagogastroduodenoscopy (EGD). This one-way order limits the availability of examination appointments. To evaluate whether EGD using insufflation of carbon dioxide (CO2), which is rapidly absorbed by the gastrointestinal mucosa, preserves the image quality of AUS performed subsequently, we designed a non-inferiority test in which each subject underwent AUS, EGD with CO2 insufflation, and a second AUS, in that order. All saved AUS moving images were randomized and imaging quality was evaluated at 16 organs using a four-point Likert-like scale that divides the depiction rate by 25%. Sample size was calculated to be 26 using the following: non-inferiority margin of –0.40 corresponding to depiction rate of –10%, difference of means of 0.40, common standard deviation of 1.25, power of 90%, and 1-sided α-level of 0.025. We enrolled 30 subjects. The mean and 95% confidence interval (CI) of the image quality score of all 16 organs at pre- and post-EGD AUS in the 30 subjects were 3.54 [3.48–3.60] and 3.46 [3.39–3.52], respectively. The difference in the means was 0.08 of the scores, corresponding to a 2% depiction rate. The effect size was 0.172. The image quality of post-EGD AUS was not inferior, as demonstrated by the 97.5% CI of the difference, which did not cross the non-inferiority margin of –0.40. In conclusion, the use of CO2 for insufflation in EGD does not cause much deterioration in the image quality of AUS performed subsequently. Therefore, it is permissible to perform EGD prior to AUS, which is expected to improve the efficiency of examination setup.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.